GB
We are pleased that our new Bright Control PRO III is able to meet the frequently
expressed customer wish for a device that can be operated with 35W, 50W and
70W Bright Sun lamps. You have full flexibility and can also easily change lamps
e.g. according to the season. The device can easily be adjusted to the desired
wattage on the side and is even simpler in operation than the predecessor.
As a production partner, we were able to win Philips - one of the leading manuf-
acturers of metal vapor lighting technology. Together we ensure that the Bright
Control PRO III will achieve optimal radiation levels for the animals. Please note
that when other ballasts are used, even from Philips, other radiation values
may occur as the manufacturers optimize their products for other lamps. Espe-
cially concerning with the UV performance this can be responsible for distinct
differences, as independent measurements show.
Lucky Reptile can ensure the optimal function of the Bright Sun and its spectrum
only in combination with Lucky Reptile ballasts and lighting equipment. The lu-
minaire is an important component and must be specially approved for use with
metal vapor lamps. Most porcelain sockets are NOT approved for use with metal
vapor lamps! Correspondingly, we recommend Lucky Reptile Thermo Socket pro-
ducts. Items with a plug-in connection that is suitable for Bright Control can be
identified by the mark „PRO".
Choosing the wattage
Attention: The wattage can be selected over a switch on the side of
the device. Make sure that the selection corresponds to the wattage
of the used lamp. Changing the wattage must only be done if the
lamp is disconnected from power supply!
Installation using Lucky Reptile Plug and Play
Luminaires
Install the Plug and Play luminaire as described in its manual. Plug the con-
nector (male) of the Plug and Play luminaire into the female connector of the
Bright Control ballast. Potentially available power cables of the Plug and Play
luminaire are not needed.
Screw the Bright Sun UV lamp into the socket. Make sure that it is fitting properly
and has good contact to the electrical parts of the socket.
Plug the Bright Control PRO III into the wall socket. The lamp should now ignite
and rise continually in brightness. If the ignition phase takes a long time or
ignition is not possible, check if the lamp is correctly screwed into the socket.
Installation of other lampholders and luminaires must only be done by a pro-
fessional electrician. It is the responsibility of the user to check if such a combi-
nation is permitted and the product safety is maintained. Please note that only
a few lampholders are suitable for use with metal halide lamps. Best to attach
other luminaries by using the connector system. Compatible male connectors
are available separately.
2
Manual - Bright Control PRO III
• It has to be ensured that the device cannot fall into water.
• Secure the device with screws in the destined holes against movement and
accidental drops
• The ambient temperature limit during operation may not fall below and ex-
ceed -20°C and 45°C respectively.
• The device is designed for use in dry and clean rooms.
• At formation of condensed water a period of acclimatisation of up to 2h has
to be ensured.
• Protect the device from moisture, spray water and impact of heat!
• The distance between ballast and lamp may not exceed 2m
• Do not undertake any modification and do not open the case.
• Device and sensor cords have to be checked always for signs of damage. If a
defect is discovered the device has to be put out of operation immediately.
The same applies if the device has come into contact with fluids.
• Generally it should be verified if the device is applicable for the application at
hand before putting it into operation!
• In case of doubt consultation of experts or the manufacturer of the employed
devices is required.
• The device is designed for use with metal halide lamps. Make sure that the
correct wattage is used. Ensure that no other lamp types are used.
• The device has to be installed in a way that it cannot be touched during ope-
ration
• Only touch the device if disconnected from main power supply.
• The device gets hot during operation
• Before lamp change the device has to be disconnected from power supply
• The ballast needs to be disconnected from the power supply if the wattage
is supposed to be changed over the switch. During operation the switch must
not be changed!
• During ignition phase voltages of approx. 5 kV can occur
• If the lamp does not ignite that device will power down and will re-try ignition
after 1-2 minutes
The warranty expires in case of modification and repair attempts as
well as damaging by force or inappropriate usage.
Neither a guarantee nor any liabilities for detriments or consequen-
tial damages in relation with this product will be assumed.
In case of warranty claims or repairs contact your specialist dealer.
Voltage:
Max. Ignition Tension Uotw (peak)
Max. Operating Temperature tc
Ambient Temperature ta
Operating conditions
Important Information:
Warranty
Technical Data
220-240 V~ 50/60 Hz
3,0 - 5 kV
80°C
-20° bis +45°C