VACUUM

Use the quick-connect couplings to connect the hoses to the A/C system, bearing in mind that
BLUE must be connected to the low pressure side and RED to high pressure. If the system is
equipped with a single quick-connect coupling for high or low pressure, connect only the
relative hose.
From the MANUAL PROCEDURE, select VACUUM, the following screen will be displayed:
use the KEYPAD to insert the new value of the VACUUM TIME, press OK to confirm, BACK to
return back.
NOTE: LEAK CHECK could be not displayed (depending of machine model).
NOTE: use the VACUUM SETTING to change the duration of the LEACK CHECK.
NOTE: if selected VACUUM TIME is lower 15 minutes the following popup warning will be
displayed:
Press YES to continue, or press NO to go back.
Type the plate of the car, press OK to confirm. BACK to return back.
NOTE: the numerical keys include an alphabet that is used similar to text messaging; for
example: press "2" once to display "A", twice to display "B", three time for "C", four time for "2".
INSTRUCTIONS MANUAL
R134a
MANUAL PROCEDURE
VACUUM TIME
LEAK CHECK
UV
GAS FILLING
LP
HP
R134a
MANUAL PROCEDURE
The selected vacuum time is lower
than 15 minutes. The leak check
could not be reliable. Continue?
YES
NO
VACUUM
R134a
MANUAL PROCEDURE
Inset vehicle
Plate number:
VACUUM
-43-
HP+LP