1. Remove screw (A) and lift off the cover (B) above
the handle cables.
B
2. Remove the 3 screws that holds the handle.
3. Remove the handle and position it by the product.
Make sure that the cables are not damaged.
5.4.1.1 To disassemble the front handle and start
inhibitor
1. Remove the front handle and the right chassis half.
2. Disassemble the gear housing and motor. See
remove the gear housing and the motor from the
chassis on page 12 .
3. Disconnect the handle cables (A) from the control
unit and remove them through the hole (B) in the
chassis.
A
B
10 - Repair instructions
A
WARNING: The spring can eject and cause
injury. Put on protective goggles.
4. Remove the 10 screws and carefully remove the
handle half.
5. Remove the relay with cables (C) and the loop (D)
out of the handle.
6. Lift the start inhibitor (E), the 3 plastic clips (F), the 3
springs (G) and the spring (H) out of the handle.
To
G
H
G
F
5.4.1.2 To assemble the start inhibitor and the front
handle
CAUTION: Make sure that the cables are set
correctly to prevent damage.
D
C
F
G
E
580 - 001 - 27.03.2018
F