130526 THREE ST GE FILTER WITH REGUL TORS
DESCRIPTION
The three stage filter unit, with two self-
relieving regulators, is designed to be a
point of use system. It is designed to
provide clean air for a paint spray gun,
breathable air unit and waterborne paint
dryers. It is capable of removing dirt,
water, oil, liquid aerosols, sub-micron
particles, oil vapors and odors.
SPECIFIC TIONS
ir Flow: 65 SCFM @ 90 PSIG
Max. Pressure: 150 PSIG
Max. Temperature: 150°F
Regulated Pressure Range: 2-125 psig
BRE THING IR REQUIREMENTS
Supplied breathing air, as defined by
OSH
29 CFR 1910.134(i), NIOSH 42 CFR
84.141, and CS
C N 3-Z180.1-00 MUST
meet or exceed the following requirements
for Type 1-Grade D breathable air, as
defined in Compressed Gas
(CG -G7-1-1997):
Contaminant
OSH
Oxygen
19.5-23.5%
Carbon Monoxide
10
(ppm v/v)
Carbon Dioxide
1,000
(ppm v/v)
Oil (Condensed
Hydrocarbons)
5
mg/m
3
"lack of
Odor
noticable
odor"
Risk of illness or death. Carbon monoxide
can cause nausea, fainting or death. Stop
using if carbon monoxide is present. This
unit does not remove carbon monoxide.
carbon monoxide monitor should be incor-
porated into your air supply line to warn of
the presence of carbon monoxide.
It is up to the employer to assure that the
air compressor is properly maintained, that
the air compressor intake is located in a
clean contaminate free location and that
the air compressor is drawing in typical
atmospheric air, meeting all of the national
and local requirements for breathing air.
INLET IR
ssociation
DR IN
CS
20-22%
<5m L/m
3
500m L/m
3
1mg/m
3
"free of any
detectable
odor"
This filter unit does not remove or filter
Carbon Monoxide (CO). It is up to the
employer to ensure that the level of CO
does not exceed the maximum national or
local allowed level. The recommended
method to assure that the CO level is not
exceeded is to install a carbon monoxide
monitor and alarm.
This filter unit will only remove particulate
matter, water, oil and odor. This filter unit
will meet the particulate matter, oil and
odor requirements of Type 1-Grade D
Breathable
ir, CS -Z180.1 when:
• The filter unit is connected to a
compressed air source:
° The compressor is properly main-
tained
RECOMMENDED INST LL TION
130526 SSEMBLY
UNION
1/2 NPT
1
ST GE
2
ST GE
ST
ND
Liquid & dirt
Liquid aerosol
removal
& sub-micron
particle
40 microns
removal
Replace
0.01 microns
element
every
Replace
3 months
element
when
indicator is
raised halfway
ir and Compressed Breathing
Service Instruction
SI-6-18-12-
Replaces SI-6-18-12
REPL CEMENT
INDIC TOR
OK
REPL CE
ELEMENT
CHECK WITH
IR FLOWING
3
ST GE
RD
Charcoal
adsorber
Oil vapor &
odor removal
Replace
element every
six weeks
(or sooner
if odors
are present)
° The air compressor intake is located
in a clean contaminate free location
° The air compressor is drawing in
typical atmospheric air, meeting all of
the national and local requirements
for breathing air
• The filters are properly maintained
•
properly operating CO monitor is
installed
OUTLET
IR
1/4 NPSM
OUTLET
OUTLET
IR
1/4 NPSM
OUTLET