Pall UR310 Serie Instrucciones De Mantenimiento página 4

Tabla de contenido

Publicidad

UR310
R E T U R N L I N E F I L T E R S
7
Filter element servicing
During servicing, the external surfaces of the filter assembly
must be cleaned to remove any dust deposits.
Servicing must be conducted using suitable tools that do not
present a hazard.
Servicing must not be carried out when a potentially explosive
atmosphere is present.
CAUTION:
Filter elements should be replaced upon indication or
at specified intervals, six months maximum. Failure
to change the element will cause the filter to go
on bypass.
Refer to Service Parts List (Section 9) for item numbers for
applicable replacement element series. Remove and replace
element as follows:
7.1
Turn off and depressurize the system.
WARNING:
FAILURE TO DEPRESSURISE THE FILTER
BEFORE SERVICING ELEMENT COULD RESULT
IN EXPLOSIVE LOSS OF FLUID, DAMAGE TO
EQUIPMENT AND POSSIBLE PERSONAL INJURY.
7.2
For UR310 series (cover service):
Open vent plug (7) at the top of the filter one and
one-half turns.
Open drain plug (7b) on the filter head and drain fluid
into a suitable waste receptacle. Replace and torque
tighten drain plug to 12ft/lb or 16Nm. Unscrew and
remove cover (3) from tube (2) counter-clockwise when
viewed from above. It may be necessary to use a 1"
socket wrench on the hexagon on the cover (3) to
loosen the cover initially.
NOTE: The UR310 series assembly is equipped with Pall's
'Auto-Pull' element extraction mechanism to facilitate element
removal. While removing the cap, tabs on the element endcap
lock into hooks in the cap and the element is automatically
pulled from the nipple.
7.3
For UR310H series (head service):
Open drain plug (7) at the bottom of the bowl assembly
(tube and cover) and drain fluid from the bowl into a
suitable waste receptacle. Replace and torque tighten
drain plug to 12 ft/lb or 16 Nm. Unscrew and remove the
bowl assembly (2 and 3) from head (1) counter-clockwise
when viewed from below. It may be necessary to use a 1"
socket wrench on the hexagon on the cover (3) to loosen
the cover initially.
7.4
Element replacement (UE310 Series): Remove filter
element (8), if already fitted, and carefully inspect the
interior surface (flow through the element is in-to-out) for
visible contamination. Normally no dirt should show, but
visible dirt or particles can be an early warning of
system component failure. Discard both the filter
element and its O-ring. The filter element is NOT
CLEANABLE. Any attempt to clean the filter element can
cause degradation of the filter medium and allow
contaminated fluid to pass through the filter element.
UR310 Series
s e r v i c e i n s t r u c t i o n s
WARNING:
DO NOT ATTEMPT TO CLEAN OR RE-USE THE
ELEMENT.
ONLY USE GENUINE PALL REPLACEMENT FILTER
ELEMENTS. USE OF SUBSTITUTE ELEMENTS MAY
INVALIDATE PRODUCT WARRANTY.
7.5
DO NOT run the system without a filter element installed.
For UR310 series: check that the O-ring (4) between the
cover (3) and tube (2) is not damaged.
For UR310H series: check that the O-ring (5) between
the tube (2) and head (1) is not damaged.
Use the replacement filter as indicated by the part
number on the element endcap.
7.6
Lubricate element O-ring with clean system fluid.
Reinstall element in the shell assembly. Lightly lubricate
cover-to-head or tube-to-head (as applicable) O-ring
with clean system fluid and reassemble the housing until
thread bottoms. Hand tighten only.
7.7
Bleed the filter by filling the filter until all air bleeds
through the vent plug(7), then torque tighten the vent
plug to 12 lb/ft or 16Nm. Check for leaks as per
section 4.8.
7.8
After element change ENSURE DIFFERENTIAL
PRESSURE DEVICE IS RESET. Brass visual and
electrical and stainless steel electrical switches reset
automatically. When system reaches normal operating
temperature, check that the electrical switch and/or
visual warning button/flag has not actuated. If visual
indicator actuates due to a cold start condition, reset
again as per section 6.
8
Warranty, Limitation of Liability and
Remedies
THERE IS NO WARRANTY OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE WITH RESPECT
TO ANY OF THE PRODUCTS, NOR IS THERE ANY OTHER
WARRANTY EXPRESS OR IMPLIED, EXCEPT AS PROVIDED
FOR HEREIN.
For a period of twelve months from the date of delivery
from Seller or three thousand hours of use, whichever
occurs first (the "Warranty Period"), Seller warrants that
products manufactured by Seller when properly installed
and maintained, and operated at ratings, specifications and
design conditions, will be free from defects in material and
workmanship. By way of explanation and not limitation, the
Seller does not warrant the service life of the filter element
as this is beyond the Seller's control and depends upon the
condition of the system into which the filter is installed.
Seller's liability under any warranty is limited solely (in Seller's
discretion) to replacing (FOB original ship point), repairing
or issuing credit for products that become defective during
the Warranty Period. Purchaser shall notify Seller promptly in
writing of any claims and provide Seller with an opportunity to
inspect and test the product claimed to be defective. Buyer
shall provide Seller with a copy of the original invoice for the
product, and prepay all freight charges to return any products
to Seller's factory, or other facility designated by Seller. All
claims must be accompanied by full particulars, including
system operating conditions, if applicable.
4

Publicidad

Tabla de contenido
loading

Tabla de contenido