Urmet K-Steel 1156 Manual Del Usuario página 7

Módulo de apertura de puerta con teclado por códigos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Installation scheme
LOBBY KEY
POSTMAN KEY
CLOCK CONTACT
MAINS~
• When the installation is completed connect the
door release module to the power supply and
make sure that power between the terminals +/~
and -/~ is available.
MAXIMUM INSTALLATION DISTANCES AND
CABLE SECTIONS
Table 1
MAXIMUM DISTANCE
Door release module → Power supply
Door release module → Electric lock
Door release module → Lobby push-button
Door release module → Postman push-button
Door release module → Clock switch
TYPE OF CABLES TO BE USED
The electrical cable to be used for the connections
can be standard single core wire of suitable section
as specified in table 1.
DS1156-001A
KOMBI DOOR
RELEASE MODULE
WITH CODE KEYBOARD
ELECTRIC
LOCK
TRANSFORMER
Ref. 9000/20A
10m
25m
1 mm
2
1,5 mm
2
1 mm
2
1,5 mm
2
0,5 mm
2
PROGRAMMING
Programming of the door release module
The programming of the door release module is
done in three steps:
• Step 0: Password confirmation or password change
• Step 1: Programming of door release time
• Step 2: Programming of the 8 door release codes
Confirmation or change of the password
There can be two cases:
a)
password is known: push in sequence the
keys
password followed by the key
• If the password is correct three confirmation
beeps will follow.
• If the password is wrong a single 5 second beep
follows and the module goes back to its normal
operation mode.
At this point, in order to confirm the existing password
push the
with step 1.
In order to introduce a new password, enter the 6
digits and then push the
will continue with step 1.
50m
2,5 mm
2
b) password has never been introduced or is
not known: press three times, in a time interval
2,5 mm
2
of 6 seconds, the push-button on the rear side
of the module; then enter the new 6 digit password
and press the
tinue with step 1.
NOTE: In order to exit from the programming phase
at any moment press the "X" key for longer than
three seconds. If no keys are depressed in the
following time period, after approximately two
minutes the unit goes automatically back to normal
operation mode and a 5 second note is generated
as confirmation.
NOTE: The Password must always have 6 digits .
"X"
, then enter the 6 digit
key and the program will continue
key. Again the program
key. The program will con-
.
7