Important information
Maintenance and Care
Clean the Remote Control using a damp cloth. Never use household cleaning products
(washing powder, soap, etc.) or alcohol to clean the device.
When the Remote Control is not in use, turn it off and store it safely.
Protect the Remote Control from excessive moisture (bathing, swimming) and heat
(radiator, car dashboard).
Protect it from excessive shock and vibration.
General warnings
Keep this device out of reach of children.
The Remote Control uses low-powered digitally coded transmissions in order to
communicate with other wireless devices. Although unlikely, nearby electronic devices may
be affected. In such cases, move the Remote Control away from the affected electronic
device.
When using the Remote Control and it is affected by electromagnetic interference, move
away from the source of the interference.
General precautions
Do not use this device in locations where the use electronic devices are prohibited.
X-ray radiation (e.g., CT/MRI scans) may adversely affect the functioning of this device.
Switch it off before undergoing the procedure and keep it outside the room.
High-powered electronic equipment, larger electronic installations and metallic structures
may impair and significantly reduce the operating range.
Your sound processors and this device were given unique communication codes during
fitting. This ensures that the device will not affect sound processors worn by others.
Do not alter or modify this device.
Opening the Remote Control might damage it. If problems occur that cannot be resolved,
consult your hearing care professional.
The Remote Control may only be repaired by an authorized service centre.
Do not use the Remote Control in areas where RF transmission is prohibited, e.g., in
airplanes, etc.
Only connect the Remote Control to connections for which it is explicitly intended.
Built-in battery care
Please observe the following:
Your product is powered by a rechargeable battery. A new battery performs optimally after
two or three complete charge and discharge cycles.
The battery can be charged and discharged hundreds of times, but will eventually wear out.
Unplug the charger from the mains socket and the product when not in use.
If left unused, a fully charged battery will lose its charge over time.
Leaving the product in hot places will reduce the battery's capacity and service life.
A product with a cold battery may not work temporarily, even if fully charged. Battery
performance is particularly limited in temperatures well below freezing.
Battery warning
Caution: The battery used in this product may present a risk of fire or chemical burn if
misused.
The battery in your product cannot be removed or replaced by the user. Do not attempt to
open the product. Any attempt to do so may result in damage. Using other batteries may
present a risk of fire or explosion and void the warranty.
Only recharge the Remote Control with the recharger that was supplied with the product.
Dispose of batteries according to local regulations. Please recycle when possible.
Do not dispose of the battery as household waste or in a fire as it may explode.
Charger care
Please observe the following if the product is supplied with a charger.
Do not attempt to charge your product with anything other than the AC adapter provided.
The use of other chargers may damage or destroy the product and could be dangerous. Use
of other chargers may invalidate any approval or void the warranty.
For availability of approved accessories, please check with your hearing care professional.
Charge the product according to the instructions provided.
Charger warning
When you disconnect the power cord or any accessory, grasp and pull the plug, not the
cord.
Never use a charger that is damaged.
Do not attempt to disassemble the charger because it may expose you to a dangerous
electric shock.
Incorrect reassembly can cause electric shock or fire when the product is subsequently used.
Avoid charging your product in extremely high or low temperatures and do not use the
charger outdoors or in damp areas.

Technical specifications

Temperature test, transport and storage information
Operating range
Up to 3 meters
Wireless
2,4 GHz
Operating temperature
0 to 55 °C
Storage temperature
-20 to 60 °C
The product is subject to various tests in temperature and damp heating cycling between -25
°C and +70 °C according to internal and industry standards.
Wireless Accessory type designations for models included in
this User Manual are:
FCC ID QZ3RC-2, IC 8039C-RC2, IC model: RC-2
Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation. Note: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications can void the user's authority to operate the equipment.
List of countries:
The products are in compliance with the following regulatory requirements:
In EU: the device conforms to the Essential Requirements according to Annex I of
Council Directive 93/42/EEC for medical devices (MDD) and essential requirements
and other relevant provisions of Directive 1999/5/EC (R&TTE). The declaration of
conformity may be consulted at www. cochlear.com.
Products with wireless functionality are intended for sale in countries within the
European Economic Area as well as Switzerland. Specification of restrictions: You
are not allowed to operate the equipment within 20 km of the centre of Ny Ålesund,
Norway.
In US: FCC CFR 47 Part 15, subpart C, section 15.249.
Other identified applicable international regulatory requirements in countries outside
the EU and US. Please refer to local country requirements for these areas.
Products are in compliance with EN 300 328.
In Canada the Remote Control is certified under the following certification number:
IC:8039C-RC2.
This device complies with Industry Canada license exempt RSS standard(s)
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil
numérique de la classe B est conforme à la norme NMB-003 du Canada.
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device. L'exploitation est autorisée aux deux
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur
de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
Equipment includes RF transmitter.