Important!
Switching over the catch lever will shut off the
torque function. Please note: The operating range
of the wrench is 40 - 200 Nm. Never continue to
operate the wrench after it has released (click
sound).
Caution:
Never use the wrench to loosen corroded bolts
and nuts!
Never use the ratchet head with adapters for other
square end sizes - use only the 1/2" square drive
wrench sockets! The square end of the ratchet
head is geared to the torque to be set with the
mechanism of the torque wrench.
Notes
• Only operate the torque wrench by grasping its
handle 2 (Fig. 1)!
• Do not use any extensions! This would not cor-
rectly signal the adjusted value.
• Never adjust the torque value over or under the
limit of the scale!
• Treat your torque wrench with the same care as
for a measuring instrument!
• After use, the mechanics of the torque must be
destressed by adjusting to the lowest torque
value.

Maintenance and inspection

To relieve the pressure spring after use, adjust
to a low torque value!
• Never disassemble the torque wrench yourself!
For all repairs or malfunctions, please send the
wrench to our central service. The address is
printed on the last page of these instructions.
Should calibration become necessary, please
return the device to the manufacturer. You will
find the address on the back page of these in-
structions.
• Clean the device by dry methods - do not im-
merse in benzine or solvents!
- 7 -