5. Trouble Shooting
Use the table below to solve minor problems.
Problem
Possible Cause
No LED display on the
Low battery.
front panel.
Battery fault.
The UPS is not turned on.
Alarm continuously
The UPS is overload.
sounds when the
mains is normal.
UPS fault
Alarm sounds every 2
Battery defect.
seconds when the
mains is normal.
Charging board is damaged. Return the unit to the service center.
When power fails,
The UPS is overload.
back-up time is
Battery voltage is too low.
shorten.
Battery defect. It might be
due to high temperature
operation environment, or
improper operation to battery.
The mains is normal
Power cord is loose.
but LED is flashing.
6 Specifications
Model
Nano 400
CAPACITY
400 VA / 240 W
INPUT
Voltage
Voltage Range
Frequency
OUTPUT
Voltage Regulation
Transfer Time
Waveform
BATTERY
12 V / 4.5 AH x 1
Type & Number
Charging Time
PHYSICAL
Dimension (DxWxH)
228 x 82.5 x 207 mm (@ vertically stand)
Net Weight (kgs)
2.2
Environment
Humidity
Temperature
Solutions
Charge the UPS at least 8 hours.
Replace the battery with the same
type of battery.
Press the power switch again to turn
on the UPS.
Remove some loads first. Before
reconnecting equipment, please
verify that the load matches the UPS
capability specified in the specs.
Return the unit to the service center.
Replace the battery with the same
type of battery.
Remove some critical load.
Charge the UPS at least 8 hours.
Replace the battery with the same
type of battery.
Reconnect the power cord properly.
Nano 600
Nano 800
600 VA / 360 W
800 VA / 480 W
110/120 VAC or 220/230/240 VAC
90~145 VAC or 180~270 VAC
50 Hz or 60 Hz
+/-10%
Typical 2-6 ms
Simulated Sine Wave
12 V / 7 AH x 1
12 V / 9 AH x 1
8 hours recover to 90% capacity
2.7
3.1
0-90 %
0-40° C ( non-condensing)
4
Standby UPS
1. Lieferumfang
Im Lieferumfang sollten Sie folgendes finden:
- UPS Einheit
- Schnell Installationsanleitung
- Stromkabel ( nur für IEC-input Modell)
2. Produktü bersicht
Vorderansicht:
Rü ckansicht:
Quick Guide V. 1.1
Netzschalter
UPS Statusanzeige
Status der Schuld/Batterie
AC input
Ausgabe Anschluss
5
DE

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nano 600Nano 800

Tabla de contenido