Hybrid Security Control Panel
E N G L I S H
Diagram References
Appearance
1
Indicators
Components
Reset
1
AC Power
2
6
Power On
Power Off
Lock Nut
10
2
Button
2
2
System Fault
No Fault
Status
Battery
Power
2
7
2
11
Panel is added to Hik-connect account
Connector
Interface
2
3
Link
Panel is not added to Hik-connect account
Wiring
TAMPER
2
12
2
8
4
Arm/Disarm
Armed
Disarmed
Terminal
Switch
AP&STA
Network
Alarm Occurred
Device Tampered
5
Alarm
9
2
13
2
Interface
Switch
No Alarm
Note: Remove the rear cover, and some of the components and interfaces are on the rear panel.
Reset: Power on the device, the yellow status indicator will flash 3 times. Hold the reset button for 5 s to reset
the device.
Wiring and Installation
2
1. Loosen the screw on the top, press the lock nut, and open the case of the control panel.
2. Route the cables, and secure the rear cover in the installation position with the supplied
screws.
3. Fix the SIM card module (should be purchased separately) with four plastic bolts.
4. Fix the telephone module (should be purchased separately) with two plastic bolts.
5. Wire the cables.
Telephone Module Wiring
1
2
Alarm Input/Alarm Output/RS-485 Wiring
1
2
Alarm Input Wiring
e.
Dual-Zone Series Connection
a.
NC Detector
b.
NO Detector
f.
Dual-Zone Parallel Connection
c.
Unoccupied Zone
d.
Tamper-proof
2
2
Alarm Output Wiring
2
3
RS-485 Wiring: Wireless Receiver, keypad, etc.
3
Network
4
Power Supply
6. Connect the battery to the control panel.
Note: The condition of no SIM card, no battery, AC power off, or network disconnected, will cause Control Panel Fault.
7. Fix the power cables with the cable clip.
8. Close the control panel, and tighten the top screws to complete the installation.
TAMPER Screw
It is compulsory to secure the TAMPER screw.
Set Up
3
Set up via Web Client
Log Into the Web Client
Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode.
Default IP Address when connecting the network cable with computer directly :192.0.0.64
Input the device IP address in the address bar of the web browser. Create a password to
activate the device and log into the web client.
Add a Camera for the Zone
The function varies depends on the model of device.
1. Click System-Network Camera, and you can add cameras for the control panel.
2. Enter the "Device Management" page, select a zone, and select a camera to link with the zone.
You can also link a camera with the zone via APP, refer to the Security Control Panel User Manual
for details.
Configure Video-Push
You can view the alarm video via APP and email.
For detailed settings, refer to Security
Control Panel User Manual.
Set up via APP
1. Log into the App Store or Google Play and input Hik-Connect to search and install the
mobile client.
2. Log into the APP with Hik-Connect account.
3. Tap Add Device. Scan the device QR code on the rear panel(on the lable).
4. Tap Connect to a Network. Select Wireless Connection (AP) as the connection mode.
5. Push the AP/STA mode switch to the AP position, tab Confirm.
6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi , and
click Next.
7. Create a password to activate the device.
8. Push the AP/STA mode switch to the STA position.
Note: You need to enter the Verification Code (on the device lable which is pasted on the rear panel) before
activation if you add the device by entering the device serial No.(SN).
Set up via 4200 Client
1. Download and install the iVMS-4200 client.
Note: Get the client software from the official website:www.hikvision.com.
2. Enter Device Management page, click "Device - Online Device", select the device in the
Online Device List, click Edit Network Settings, change the port as 80, and click Add to Client.
Note: You should activate the device for the first usage.
Restore Default Settings
Reboot the
device. Boot the device, and hold the reset button for 5s after the Fault indictaor
flashes 3 times. The device will prompt a message to indicates the operation status.
Specification
Hybrid Security Control Panel with Plastic Case
DS-PHA20-P
DS-PHA20-W2P
Model
DS-PHA64-P
DS-PHA64-W4P
Wireless Detector
Up to 16/56
Wireless Output expander
Up to 8
Device
1 wired siren (on-board connection)
connection
Siren
2 wireless sirens
Keyfob
8, valid operation interval: 3 s
4 (DS-PHA20)
Partition
8 (DS-PHA64)
Alarm input
4 on-board zones , and 16 wired/wireless zones expadable(DS-PHA20),
Zone
or
8 on-board zones, and 56 wired/wireless zones expadable(DS-PHA64)
2 on-board outputs, and 18 wired/wireless outputs expadable (DS-PHA20),
Alarm output
Alarm output
or
4 on-board outputs, and 60 wired/wireless outputs expadable (DS-PHA64)
Scheduled arming/disarming
Supported
SMS notification
Function
Supports up to 8 mobile phone numbers
(with 3G/4G/GPRS module)
2 (DS-PHA20)
Network camera accessing
N/A
4 (DS-PHA64)
iVMS-4200 (client software)
Application
Hik-Connect (mobile client)
Application &
ISAPI: Supports client software and web client
Protocol
Protocol
Cloud P2P: Supports cloud P2P privacy protocol
DC09: ARC accessible (CID/SIA)
10M/100M Ethernet
Wired network
Network
Cellular Network
Supports report push- notification to ARC & Cloud
(with 3G/4G/GPRS module)
Standard
N/A
802.11b/g/n
64/128-bit WEP,WPA/
Encryption
N/A
WPA2,WPA-PSK/WPA2-
Wi-Fi
PSK,WPS
Configuration
N/A
AP Mode
Indoor: ≤ 50 m
Distance
N/A
Outdoor: ≤ 100 m
1, front cover tamper-proof
TAMPER Switch
Network Interface
1, RJ45 10M/100M Ethernet Interface
Telephone Interface
1, PSTN expander interface
1, extended up to 20 inputs/outputs (with RS-485 module),
and 9 wired keypads extendable (DS-PHA20),
Interface &
RS-485 Terminal
or
Component
1, extended up to 64 inputs/outputs (with RS-485 module),
and 9 wired keypads extendable (DS-PHA64)
Siren Power Interface
1, 12V
Battery Interface
Lithium battery (-P model)
Installer: 1
Administrator: 1
User
Manufactuer:1
User
Operator: 13 (DS-PHA20), 45 (DS-PHA64)
Tag
12
Operation Temperature
–10 °C to 55 °C (-4 °F to +122 °F)
Others
Operation Humidity
10% to 90% (No condensing)
Dimension (W × H × D)
Plastic Case: 220 mm (8.6") × 152 mm (6.0") × 31.5 mm(1.2")
Note: The 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9.
1
1
2
2
2
3
2
2
4
2
5
2
7
6
2
2
1
Telephone Line Cut Off Indicator
Power Indicator
Telephone Module
12VDC
Power Adapter
Keypad
Siren
Alarm
Alarm
Alarm
Lamp
Lamp
Lamp
220V~
12V
G
485+
485
N
CON101 L
12V_BELL
G
12V_AUX
G
NO/NC1 COM1
NO/NC2 COM2 NO/NC3 COM3 NO/NC4 COM4
2
3
2
2
C1
PGM1
AUX-
AUX+
D- D+
AUX-
AUX+
D- D+
OR
Dry Contact
......
3
Set up via APP
2
5
2
8
STA
AP
STA
STA
AP
STA
AP
The AP mode is only Supported by device with Wi-Fi function.
2
2 1
8
2
2
9
10
2
11
2
12
2
13
2
STA
AP
STA
AP
4
2
3
4
L
CON101
CAUTION
CABLES CAN ONLY BE ROUTED
THROUGH THE REAR PANEL. DO NOT
ROUTE THE ANTENNA WIRE THROUGH
Caustic
GND
NULL
THE ELECTRICAL BOARD
Line
Line
220V~
2K2
2K2
2K2
2K2
2K2
2K2
2K2
2K2
EOL
EOL
EOL
EOL
EOL
EOL
EOL
EOL
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
Alarm
Lamp
N.C
N.C
N.C
N.C
N.C
N.C
N.C
N.C
Z1
G
Z2
Z3
G
Z4
Z5
G
Z6
Z7
G
Z8
2
1
2
a
b
2
e
2
Security Control Panel
Peripheral Security Detector
Security
Peripheral Security Detector
Security Control Panel
Control Panel
NO
C
Local Zone
Z
NO
Z
Z
NC
2.2kΩ
2.2KΩ
2.2KΩ
8.2kΩ
C
C
C
C
C
Local Expanding
NO
C
Zone
2
c
2
d
2
f
Security
Control Panel
Local Zone
Security Control Panel
2.2K Ω
TAMPER
Z
Z
2.2kΩ
8.2kΩ
Z
NC
NC
C
C
C
C
C
Detector
Local Expanding Zone
Product Information
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information
hereinafter are for description and explanation only. The information contained in the Manual is subject to change,
without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision
website (https://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.
Trademarks
and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other
trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS
HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES
AP
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR
FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING,
AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION
OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING
NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL
NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL
PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR
ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION,
RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL
NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS
OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES
IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN
RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
2 2
2 3
CAUTION
SUITABLE FOR MOUNTING ON
CONCRETE OR OTHER
NON-COMBUSTIBLE SURFACE ONLY
2 5
2 6
2
1
3
......
2 7
CAUTION
COPER OR COPER WIRE CANNOT BE
EXPOSED AT THE ELECTRICAL TERMINAL
FCC Information
Please take attention that changes or modification not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper recycling, return this product to
your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see: www.recyclethis.info
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of
as unsorted municipal waste in the European Union. See the product documentation for
specific battery information. The battery is marked with this symbol, which may include
lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return
the battery to your supplier or to a designated collection point. For more information
see:www.recyclethis.info
This product and - if applicable - the supplied accessories too are marked with "CE" and
comply therefore with the applicable harmonized European standards listed under the RE
Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU, the
RoHS Directive 2011/65/EU
2 4
CAUTION
RISK OF EXPLOSION IF
BATTERY IS REPLACED BY AN
INCORRECT TYPE
DISPOSE OF USED BATTERIES
ACCORDING TO THE
INSTRUCTIONS
2 8
CAUTION
A TWO-POLE DISCONNECTED
DEVICE (BREAKER) SHALL BE
PROVIDED WHEN INSTALLED
UD15863B-B