Hybrid Security Control Panel
E N G L I S H
Diagram References
Wiring and Installation
1
1. Unlock the front cover with the supplied key, open the case of the control panel.
2. Fix the control panel case on the required place with three supplied screws.
3. Fix the SIM card module (Sold separately) with four plastic bolts.
4. Install the telephone module (Sold separately) with two plastic bolts.
5. Wire the cables.
1
Antenna Wiring (Wi-Fi and 3G/4G/GPRS Antenna)
1. Connect the pin of the pedestal to the terminal on the board or module.
2. Rotate and fix the antenna on the pedestal.
2
Network Wiring
3
Alarm Input/Alarm Output/RS-485/Power Supply Wiring
Power down the control panel before connecting and disconnecting accessories
and peripherals.
2
1
Alarm Input Wiring
a.
NC Detector
b.
NO Detector
c.
Unoccupied Zone
d.
Tamper-proof
2
2
Alarm Output Wiring
2
3
RS-485 Wiring: Wireless Receiver, keypad, etc.
4
2
Power Supply Wiring
4
Telephone Module Wiring
6. Close the case of the control panel. Lock the front cover with the supplied key.
Set Up
2
Set up via Web Client
Log Into the Web Client
Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode.
Default IP Address when connecting the network cable with computer directly :192.0.0.64
Input the device IP address in the address bar of the web browser. Create a password to
activate the device and log into the web client.
Add a Camera for the Zone
The function varies depending on the model of device.
1. Click System-Network Camera, and you can add cameras for the control panel.
2. Enter the "Device Management" page, select a zone, and select a camera to link with the
zone.
You can also link a camera with the zone via APP, refer to the Security Control Panel User
Manual for details.
Configure Video-Push
You can view the alarm video via APP and email.
For detailed settings, refer to Security
Control Panel User Manual.
Set up via APP
1. Log into the App Store and input Hik-Connect to search and install the mobile client.
2. Log into the APP with Hik-Connect account.
3. Tap Add Device. Scan the device QR code on the rear panel (on the lable).
4. Tap Connect to a Network. Select Wireless Connection (AP) as the connection mode.
5. Push the AP/STA mode switch to the AP position, tap Confirm.
6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi, and
click Next.
7. Create a password to activate the device.
8. Push the AP/STA mode switch to the STA position.
Note: You need to enter the Verification Code (on the device lable which is pasted on the rear panel) before
activation if you add the device by entering the device serial No.(SN).
Set up via iVMS-4200 Client Software
1. Download and install the iVMS-4200 client software.
Note: Get the client software from the official website:www.hikvision.com.
2. Enter Device Management page, select the device in the Online Device List, click Edit
Network Settings, change the port as 80, and click Add to Client.
Note: You should activate the device for the first usage.
Specification
Hybrid Security Control Panel with Metal Case
DS-PHA20-M
DS-PHA20-W2M
Model
DS-PHA64-M
DS-PHA64-W4M
Wireless Detector
Up to 16/56
Wireless Output expander
Up to 8
Device
1 wired siren (on-board connection)
connection
Siren
2 wireless sirens
Keyfob
8, valid operation interval: 3 s
4 (DS-PHA20)
Partition
8 (DS-PHA64)
Alarm input
4 on-board zones , and 16 wired/wireless zones expadable(DS-PHA20),
Zone
or
8 on-board zones, and 56 wired/wireless zones expadable(DS-PHA64)
2 on-board outputs, and 18 wired/wireless outputs expadable (DS-PHA20),
Alarm output
Alarm output
or
4 on-board outputs, and 60 wired/wireless outputs expadable (DS-PHA64)
Scheduled arming/disarming
Supported
SMS notification
Function
Supports up to 8 mobile phone numbers
(with 3G/4G/GPRS module)
2 (DS-PHA20)
Network camera accessing
N/A
4 (DS-PHA64)
iVMS-4200 (client software)
Application
Hik-Connect (mobile client)
Application &
ISAPI: Supports client software and web client
Protocol
Protocol
Cloud P2P: Supports cloud P2P privacy protocol
DC09: ARC accessible (CID/SIA)
Wired network
10M/100M Ethernet
Network
Cellular Network
Supports report push- notification to ARC & Cloud
(with 3G/4G/GPRS module)
Standard
N/A
802.11b/g/n
64/128-bit WEP,WPA/
Encryption
N/A
WPA2,WPA-PSK/WPA2-
Wi-Fi
PSK,WPS
Configuration
N/A
AP Mode
Indoor: ≤ 50 m
Distance
N/A
Outdoor: ≤ 100 m
TAMPER Switch
1, front cover tamper-proof
Network Interface
1, RJ45 10M/100M Ethernet Interface
Telephone Interface
1, PSTN expander interface
1, extended up to 20 inputs/outputs (with RS-485 module),
Interface &
and 9 wired keypads extendable (DS-PHA20)
Component
RS-485 Terminal
1, extended up to 64 inputs/outputs (with RS-485 module),
and 9 wired keypads extendable (DS-PHA64)
Siren Power Interface
1, 12V
Battery Interface
Storage battery (-M model)
Installer: 1
Administrator: 1
User
User
Manufactuer:1
Operator: 13 (DS-PHA20), 45 (DS-PHA64)
Tag
12
Operation Temperature
–10 °C to 55 °C (-4 °F to +122 °F)
10% to 90% (No condensing)
Others
Operation Humidity
Dimension (W × H × D)
Metal Case: 351.4 mm (13.8") × 261.4 mm (10.3") × 93.3 mm (3.7")
Note: The 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9.
1
2 2
2 1
CAUTION
SUITABLE FOR MOUNTING ON
CONCRETE OR OTHER
NON-COMBUSTIBLE SURFACE ONLY
Z1
C
Z2
Z3
C
Z4
Z5
C
Z6
N.C
N.C
N.C
N.C
N.C
N.C
N.O
N.O
N.O
N.O
N.O
N.O
2K2
2K2
2K2
2K2
2K2
2K2
EOL
EOL
EOL
EOL
EOL
EOL
Only for device with
1
2
8 on-board zones
a
2
Security Control Panel
Security Control Panel
Peripheral Security Detector
Z
Z
NC
2.2KΩ
C
C
C
c
2
Security Control Panel
2.2K Ω
Z
Z
C
C
2
Set up via APP
AP
STA
AP
STA
2
5
AP
STA
The AP mode is only Supported by device with Wi-Fi function.
2 3
Z7
C
Z8
C1 PGM1
C2 PGM2 C3 PGM3
C4 PGM4 AUX
N.C
N.C
Alarm
Alarm
Alarm
Alarm
Lamp
Lamp
Lamp
Lamp
N.O
N.O
Only for device with
8 on-board zones
2K2
2K2
EOL
EOL
2
2
b
2
C1
PGM1
AUX-
AUX+
D- D+
Peripheral Security Detector
NO
2.2KΩ
C
Dry Contact
2
d
TAMPER
CAUTION
COPER OR COPER WIRE CANNOT BE
EXPOSED AT THE ELECTRICAL TERMINAL
D E T E C T OR
8
2
AP
STA
Wi-Fi
2 4
2 5
AUX+
BELL
BELL+
D
D+
DC
DC+
BAT
BAT+
Siren
Lead-acid
Battery
RS-485
15VDC
Power Adapter
2
2
4
2
3
AUX-
AUX+
D- D+
DC-
DC+
OR
......
Product Information
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
ALL RIGHTS RESERVED.
Any and all information, including, among others, wordings, pictures, graphs are the properties of
Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinafter referred to be
"Hikvision"). This user manual (hereinafter referred to be "the Manual") cannot be reproduced,
changed, translated, or distributed, partially or wholly, by any means, without the prior written
permission of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties,
guarantees or representations, express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to the Axiom Security Control Panel Kit.
The Manual includes instructions for using and managing the product. Pictures, charts, images and all
other information hereinafter are for description and explanation only. The information contained in the
Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the
latest version in the company website (http://overseas.hikvision.com/en/).
Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement and other Hikvision's trademarks and logos are the
properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned below are the
properties of their respective owners.
This product and - if applicable - the supplied accessories too are marked with "CE" and
comply therefore with the applicable harmonized European standards listed under the RE
Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU, the
RoHS Directive 2011/65/EU
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper recycling, return this product to
your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see: www.recyclethis.info
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of
as unsorted municipal waste in the European Union. See the product documentation for
specific battery information. The battery is marked with this symbol, which may include
lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return
the battery to your supplier or to a designated collection point. For more information
see:www.recyclethis.info
GPRS
CN1
3G/4G
MAIN
AUX
1
2
3
......
4
Telephone Line Cut Off Indicator
Power Indicator
Telephone Module
FCC Information
Please take attention that changes or modification not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation
UD15862B