STC
Nombre del Producto modelo
Programming of open door and closed door positions
5.1 Press the K1 (for 3 sec) until the number 1 is displayed on the screen (open door programming).
5.2 Press K3 and move the door to the desired final point of the open door position.
5.3 If the door is not on the desired position, press K4 to make the run shorter. Finish the position adjustment by pressing
K3 or K4.
5.4 Press K1 to confirm the position. The screen will display number 2 (closed door programming).
5.5 Press K4 and move the door to the desired final point of the closed door position.
5.6 If the door is not on the desired position, press K3 to make the door run shorter. Finish the position adjustment by
pressing K4 or K3.
5.7 Press K1 to confirm the position.
The operator will automatically open and close the door and adjust the required driving force. In case it is necessary to
increase or reduce the force, please, refer to the paragraph "Force programming".
Warning: While the movement direction test and operation checks are being performed, the risk zone should be free of
objects and persons, and a security distance for the door motion area should be kept.
5.8 The door is now ready for its normal operation.
Note: The security systems should be tested periodically in order to guarantee their optimal conditions at all times.
Adjustments
Force programming
Normally, this adjustment is not necessary since the force is automatically configured. However, in some rare cases, the force
may be adjusted by the installer.
6.1 Press the K1 until number 3 is displayed on the screen (manual force programming).
6.2 Press K3 to increase the force and K4 to reduce it (minimum force 1, maximum force 9).
6.3 Press K1 to confirm.
6.4 If the operator detects any obstacle, the door will reverse its course for 15 cm.
Additional programming The operator features three switchable operation modes, operation with photocell, automatic closing
mode and LOCK DOOR mode.
7.1
Switch photocell ON / OFF. Before selecting any mode, ensure that the photocell has been properly installed.
7.1.1 Press K4 until the symbol (I I) is displayed.
7.1.2 Press K3 to switch the photocell on (H for photocell ON).
7.1.3 Press K4 to switch the photocell off (II for photocell OFF)
7.1.4 Press K1 to confirm.
7.2
Automatic closing programming.
7.2.1 Press K3 until the symbol (-) is displayed.
7.2.2 Pressing K3 or K4 will prolong or reduce the automatic closing time in 15 seconds. (1= 15 sec 9= 135 sec)
The automatic closing will be disabled when 0 is displayed on the screen. Press K1 to confirm. The automatic closing can be
switch on even when the photocell is not
7.3
Press the K1 until number 4 is displayed, the system is now in lock door mode.
7.3.1 Press K3, number 3 will be displayed on the screen and the lock door mode will be on; pressing K4 will display 0 on the
screen and disable the lock door mode.
7.4
Receiver shut down
Note: Only 3 channel remote controls support this function. With the receiver is shut down, pressing the second channel once
will activate the receiver's shut down (the operator does NOT function with remote control but it does function with the
GND/PB push-button. Pressing the third channel once will deactivate the receiver shut down mode, will put it back to its
normal operation mode again.
connected.Lock Door