7. Selection of the work frequency
For each RADSECRX receiver and relative T.CO. transmitter it is possible to select a frequency of work. This allows to be able to utilize up to a maxi-
mum of 4 R.CO. receivers on the same range of action without interferences.
For a correct functioning of the system it is indispensable that the frequency set on the RADSECRX receiver corresponds to the frequency set on the
associated transmitters.
The selection of the frequency happens with DIP 3 and 4 as reported on the following table:
8. Flat battery
The battery life is of about 2 years (5 years in power save modality). The transmitter keeps constantly under control the state of its batteries. When the
tension gets down under a pre – set value, this state is signaled to the RADSECRX associated receiver which signals it (if the buzzer is active) with 4
BEEP. If the battery is not substituted, the RADSECRX receiver will continue to regularly work until the tension of the batteries won't get down under
the minimum safety threshold. If this happens, the receiver will signal it with 5 BEEP putting itself in state of alarm .
The RADSECRX device will remain in state of alarm until the battery of the RADSECTX transmitter won't be substituted.
The substitution of the battery must be carried out by qualified personnel being necessary to open the receiver.
9. RADSECRX receiver reset
Through to the button present on the receiver it is possible, further than to carry out the programming of the transmitters (see section 5), to carry out
the reset of the device deleting all the associated transmitters. Proceed as follows to carry out the reset:
Press and keep pressed the key
1
present on the RADSECRX receiver.
DO NOT release the key on the
2
RADSECRX receiver.
DO NOT release the key on the
3
RADSECRX receiver.
DO NOT release the key on the
4
RADSECRX receiver.
5
Release the key of the receiver.
10. Programming / test key of the RADSECTX transmitter
On each transmitter a key said "programming/test key" is present and a led. The pressure of the same key during the normal functioning (so not in
programming) produces a signal that is sent to the receiver which close the contact of the relay and answers to this signal with:
Number of
BIP / BLINK
1
Regular functioning, no mistake found.
2
One or more sensitive edge on alarm or interrupted 8K2 rib
3
One or more 8K2 safety sensitive edges under short circuit.
4
Battery tension under the level of attention.
5
Battery tension under the minimum level.
6
One or more associated devices disconnected
N.B.: If one RADSECTX transmitter is in alarm but it necessary to open or close the automation in any case, it's necessary to press and keep pressed
the programming / test button of the indicted RADSECTX transmitter of the indicated and in the same time to move the automation.
WARNING: If the batteries are completely flat, it will be necessary to change them.
6-1620148 REV.2
25/10/2019
DIP 3
Frequency 1
ON
Frequency 2
ON
Frequency 3
OFF
Frequency 4
OFF
The RADSECRX receiver
emits ONE bip.
The RADSECRX receiver
emits TWO bip.
The same receiver emits a
series of close BIP.
The same receiver emits
one uninterrupted bip.
The reset is ended.
Acoustic signaling during the normal functioning
Meaning
ITA
ENG
FRA
ESP
DIP 4
ON
OFF
ON
OFF
What to do
-
Check the sensitive edges connected
Check the sensitive edges connected
Substitute the batteries of the indicted device
Substitute the batteries of the indicted device
Check each associated device