Transceiver system for RADSECTX - RADSECRX
1. Description
The system is intended as safety device for the control of gates and comprises a receiver RADSECRX (connected to the control unit) and a maximum
of 8 RADSECTX transmitters (4 for each of the two relays of the receiver) connected to the sensitive edges. It can work both with the clean NC contact
mechanical edges (connecting in series the supplied 8,2KΩ – ¼ OF Watt – if not already integrated in the edge) and with the 8,2KΩ edges. The two
contacts of the receiver (normally closed with the powered device) are independent and can be connected to the relative input of the control unit, put in
series to the stop of the control unit, or in series to the photo devices contacts. Two contacts are also present on RADSECRX receiver to be able to
carry out the self – test system.
The transmission of the signals between transmitter and receiver happens on 868 MHz band in bidirectional way.
The installation and the maintenance of the system must be carried out by qualified personnel. ERREKA can not be considered responsible
for any damages caused by an improper use, incorrect or irrational of the product.
Warning: this device can block the automation if the batteries of the mobile part is flat.
2. Configuration and electrical connections
2.1 RECEIVER RADSECRX
Dip switch
Jumper of selection
output signal
Jumper of selection power supply tension.
Right : 12Vac/dc
Left: 24Vac/dc
2.2 RADSECTX TRANSMITTER + MECHANICAL EDGE
Programming / test key
Dip switch
2.3 RADSECTX TRANSMITTER + 8,2KΩ RESISTIVE
Programming / test key
Dip switch
6-1620148 REV.2
25/10/2019
Output relay
0.5A at 42.4Vac
1A at 30Vdc
Programming / reset key
8,2KΩ ¼ of
Watt
8,2KΩ RESISTIVE
ITA
ENG
FRA
WARNING: if the power supply of the receiving unit is
carried out in alternating current (Vac), the power supply
must be got through an insulation transformer (of
security, SELV tensions) which has a limited power or
almost a protection against the short circuit.
NOTE: the signal given on output (clean contact or 8K2) to
the relay 1 and 2 depends on the position of the selection
output signal jumper.
NOTE: The level of acoustic pressure generated by the
device is less then 70 dBA.
MECHANICAL
(N.C) EDGE
WARNING: it is indispensable to
insert the resistor (supplied) in
series to the contact only when a
N.C. clean contact mechanical edge
is utilized.
WARNING: in case you use a
EDGE
resistive 8,2KΩ edge, DO NOT insert
the resistor (supplied) in series.
ESP
DEU
POR
8 / 28