Página 2
Pamir 3500/4200/5000 The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
Página 3
Pamir 3500/4200/5000 Pamir 3500 Horizontal mounting DN20 (3/4"), outside thread 2 m; 2,5 m [mm] [mm] PAFEC3510 1039 PAFEC3515 1549 PAFEC3520 2039 PAFEC3525 2549 1, 1,5 m: 4 x M8 2 m: 6 x M8 2,5 m: 8 x M8...
Página 5
Pamir 3500/4200/5000 Service hatch Fig. 1A: Open the unit. Loosen Remove Fig. 1B: To remove the front plate, the locking devices on both sides must be loosened. When the front is reinstalled, it is important to ensure that it is firmly seated in the front locks.
Pamir 3500/4200/5000 Water connection Fig. 4a: NOTE! Use a pipe wrench or a similar tool to grip the air curtain connections to prevent straining of the pipes. Fig. 4b: Filling the water coil, vertical mounting...
Página 8
Pamir 3500/4200/5000 Accessories - horizontal mounting PA34WB / PAWBL [mm] PA34WB PAWBL 52,5 20 mm Fig. 6: See separate manual for PA34WB/PAWBL. Item Type Consists of Length number 18044 PA34WB15 PAFEC 3510 / 3515 / 4210 / 4215 / 5010 / 5015...
Página 9
Pamir 3500/4200/5000 Accessories - horizontal mounting PA34CB PA34TR PA34WS (PA34VD) (PA34CB) Fig. 7: PA34TR + PA34CB + PA34VD. Fig.8: PA34WS + PA34CB See separate manual for PA34TR. See separate manual for PA34WS. Item Type Consists of Length number 18059 PA34CB15...
Página 10
Pamir 3500/4200/5000 Accessories - horizontal mounting Item Type Length number PA3XT10 19085 PAFEC 3510 130-200 mm PA3XT15 19086 PAFEC 3515 130-200 mm 19087 PA3XT20 PAFEC 3520 130-200 mm 19088 PA3XT25 PAFEC 3525 130-200 mm 19090 PA4XT10 PAFEC 4210 / 5010...
Página 11
Pamir 3500/4200/5000 Accessories - vertical mounting Accessories - vertical mounting Note! The air curtain must be secured in the wall be secured in the wall or ceiling. or ceiling. PA3VDW PA4VDW PA3JK PA4JK Fig. 11: See separate manual for PA3JK / PA4JK.
Pamir 3500/4200/5000 Control systems The air curtain must be supplemented with a control system. FCDA - FC Direct FCSA - FC Smart FCCF FCDC FCBC10 FCLAP FCCF FCDC FCBC05 FCPA - FC Pro FCBA - FC Building FCCF FCDC FCBC10...
Página 15
Pamir 3500/4200/5000 PAFEC3510/15 E PAFEC4210/15 E PAFEC5010/15 E 3510: 2 Motors 4210/5010: 3 Motors 3515: 3 Motors 4215/5015: 4 Motors Inlet sensor Outlet sensor +12V +12V FCBASEPCB REA Trafo PAFEC/ARF PAFEC/ARF PAFEC/ARF 230V~ 400V 3~ Wiring diagrams for control system in the FC manual.
Página 16
Pamir 3500/4200/5000 PAFEC3520/25 E PAFEC4220/25 E PAFEC5020/25 E A1 A2 B1 B2 D1 D2 Termination 230V IN BUS 1 BUS 2 Wiring diagrams for control system in the FC manual.
Página 18
) Applicable at water temperature 80/60 °C, air temperature, in +18 °C. ) Applicable at water temperature 40/30 °C, air temperature, in +18 °C. ) See www.frico.net for additional calculations. 5,6,7 **) Horizontal mounting and vertical mounting to the right (seen from the inside): IP24...
Página 19
) Applicable at water temperature 80/60 °C, air temperature, in +18 °C. ) Applicable at water temperature 40/30 °C, air temperature, in +18 °C. ) See www.frico.net for additional calculations. 5,6,7 **) Horizontal mounting and vertical mounting to the right (seen from the inside): IP24...
Página 20
) Applicable at water temperature 60/40 °C, air temperature, in +18 °C. ) Applicable at water temperature 80/60 °C, air temperature, in +18 °C. ) See www.frico.net for additional calculations. **) Horizontal mounting and vertical mounting to the right (seen from the inside): IP24...
1800mm. Consulte otras puerta. distancias mínimas en la figura 3. Pamir 3500 tiene una altura de instalación Para cubrir huecos más anchos, se pueden recomendada de 3,5 m. instalar varias unidades seguidas utilizando el Pamir 4200 tiene una altura de instalación...
Pamir 3500/4200/5000 Montaje en vertical destornillador antes de introducir el cable. Consulte la figura 2. El control se suministra a la Las unidades de 1,5 metros o más se pueden placa de PC mediante 230V~. montar en vertical. La cortina de aire se instala en vertical lo más cerca posible de la puerta.
Tenga en cuenta que la unidad debe ir Filtro (W) precedida de una válvula reguladora (consulte el juego de válvulas Frico). La batería de agua está protegida del polvo La batería de agua se conecta por la parte y las obstrucciones con un filtro de aire que superior de la unidad (montaje en horizontal) cubre todo su frente.
Pamir 3500/4200/5000 1. Desconecte la alimentación. agua. 2. Afloje los tornillos y levante el panel frontal. 3. Quite los tornillos que sujetan la batería a la Sujete el panel frontal en posición abierta con unidad y extráigala. el enganche previsto para ello. Consulte la 4.
Página 25
Pamir 3500/4200/5000 de FC). Seguridad • Todas las instalaciones con productos de calor En las unidades con calor eléctrico, compruebe eléctrico deben equiparse con un interruptor también lo siguiente: diferencial residual de 300 mA para protección • Compruebe la alimentación eléctrica de contra incendios.
) Aplicable a una temperatura del agua de 80/60 °C y una temperatura del aire de +18 °C. ) Aplicable a una temperatura del agua de 40/30 °C y una temperatura del aire de +18 °C ) Visite www.frico.com.es para obtener cálculos adicionales. 5,6,7 **) Montaje horizontal y montaje vertical a la derecha (visto desde el interior): IP24.
Página 30
Main offi ce Frico AB Tel: +46 31 336 86 00 Industrivägen 41 SE-433 61 Sävedalen mailbox@frico.se Sweden www.frico.net For latest updated information and information about your local contact: www.frico.net.