Descargar Imprimir esta página

Berker 7531 00 01 Manual De Instrucciones página 13

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB
Shutter operation:
• If motors are to be connected in parallel, it is absolutely necessary
to observe the instructions of the motor manufacturers. The
motors can otherwise be irreparably damaged.
• Use only shutters with limit switches (mechanical or electronic).
The limit switches of the motors connected must be checked for
proper adjustment.
• A defect of a shutter output may also result in damage to the
motor.
• Activation of the manual operation mode terminates all time
delays and the safety shutdown function in stormy weather. The
safety shutdown during stroms is reactivated when the manual
operation mode is ended.
• The manual mode permits only continuous movements (long
press) and stop (short press).
Important
Characteristics
Shutter operation:
• Switch-over time during change of movement direction adjustable
(observe the instructions of the motor manufacturer)
• movement directions lockable by software control
• Sun protection function
• Safety shutdown during storms separately adjustable for each
shutter output
• Response on bus voltage failure and return adjustable
For further characteristics, please read the corresponding EIB
product documentation.
GB

Publicidad

loading