Micron Rating.............................................................1 Micron
Flow Rate: .............................................. 0.5 GPM (1.9 LPM)
Min./Max. Operating Pressure..........................25 psi/125 psi
Min./Max. Operating Temperature........................35°F/100°F
Capacity .............................................................750 Gallons
Water Supply ........................Use only on the cold water line
This system and installation shall comply with applicable state
and local regulations. General operations and maintenance -
Replace every 6 months.
NOTICES
• Use only with municipally treated or microbiologically safe
water. Do not use with water of unknown quality without
adequate disinfection before or after your filter.
• Install this filter on the cold water line only. Do not use on
water lines exceeding 100° F (38°C). Water pressure minimum
is 25 psi and the maximum is 125 psi.
• Protect the unit from direct sunlight and freezing temperatures.
• Do not use pipe dope or similar compounds. They can ruin
plastic. Use teflon tape to seal pipe thread joints.
• Keep the unit clean with soap and water. Do not use spray
cleaners or insecticides near the unit.
• Intended for indoor, non-commercial use only.
• Safety glasses must be worn during installation.
• Tubing and hose dimensions are based on outside diameters
(OD). For water line sizes other than those listed, consult a
plumber or hardware store.
• This filter is not a water purifier and is not intended for use
with contaminated water.
• Comply with all state and local laws regarding the installation
of water treatment devices.
©2002, Omnifilter
Refrigerator/Ice Maker
®
• An activated carbon cartridge may contain a small amount of
carbon fines (very fine black powder). A new cartridge, after
installation, should be flushed with sufficient water to remove
the fines before using the water.
• The filter cartridge has a limited service life. Changes in taste,
color and flow of the water being filtered are signals that
replacement of the cartridge is or may soon be necessary.
Cartridge should be changed every 6 months or after 750 gal-
lons of water used, whichever occurs first.
• If making sweat connections, avoid exposure of the fil-
ter housing to the torch.
• The contaminants or other substances removed or
reduced by the water filter device are not necessarily in
your water.
Installation
The system and installation must comply with all state and local
laws and regulations.
(1.8 - 8.8 kg/cm)
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be
(2°C/38°C)
used on disinfected water that may contain filterable cysts.
1. Turn off the cold water supply.
2. Locate an easily accessible section of tubing between the shut
off valve and the refrigerator.
3. Cut tubing using a tube cutter - smooth out the sharp edges
of the cut tubing with a file or steel wool. Do not cut tubing
on an angle. Tubing cut on an angle may leak during service.
NOTICE: Install the unit with the directional arrow in line with
the water flow. See Figure 1.
Figure 1
Printed in U.S.A.
Inline Water Filter
INSTALLATION INSTRUCTIONS
R400 Series A
Supply side
of Filter
Housing.
From
the
Water
Supply
Refrigerator
side of
Filter Housing.
To
the
3699 02
Refrigerator
OM644 (Rev. 8/26/02)

Publicidad

loading

Resumen de contenidos para Omnifilter R400 A Serie

  • Página 1 Refrigerator/Ice Maker ® Inline Water Filter 293 Wright Street • Delavan, WI 53115 1-800-937-6664 • www.omnifilter.com INSTALLATION INSTRUCTIONS R400 Series A • An activated carbon cartridge may contain a small amount of carbon fines (very fine black powder). A new cartridge, after installation, should be flushed with sufficient water to remove the fines before using the water.
  • Página 2: Important Notice

    1. Turn off the cold water supply to the filter. For further operating, installation, or 2. Remove the tubing from the ends of the unit. See Figure 2. maintenance assistance: Omnifilter ® lean Water Solutions 293 Wright Street, Delavan, WI 53115...
  • Página 3 Filtre à eau Réfrigérateurs/ machines à glaçons INSTRUCTIONS D’INSTALLATION R400 Series A • Une cartouche au charbon actif peut contenir de petites par- ticules de charbon. Après avoir posé une cartouche neuve, il faudra la rincer avec suffisamment d’eau pour éliminer toutes les fines et ceci avant de consommer de l’eau.
  • Página 4 2. Débrancher le tube des extrémités du filtre. Se reporter à la Figure 2. Pour de plus amples renseignements concernant le fonctionnement, l'installation ou l'entretien : Omnifilter ® lean Water Solutions 293 Wright Street, Delavan, WI 53115 Pousser sur la...
  • Página 5: Refrigerador/Máquina De Hielo Filtro De Agua En Línea

    Refrigerador/Máquina de hielo Filtro de agua en línea INSTRUCCIONES DE INSTALACIÓN R400 Series A - Un cartucho de carbón activado puede contener una pequeña cantidad de finos de carbón (polvo negro muy fino). Es importante dejar correr suficiente agua por un car- tucho nuevo, después de la instalación, para eliminar los finos antes de usar el agua.
  • Página 6 1. Cierre la llave de suministro de agua fría hacia el filtro. instalación y mantenimiento: 2. Saque la tubería de los extremos de la unidad. Ver la Figura 2. Omnifilter ® lean Water Solutions 293 Wright Street, Delavan, WI 53115 800-937-6664 www.omnifilter.com...