Parts List - Water Ace R106 Manual De Instalación

Bombas de uso múltiple
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PARTS REPLACEMENT INSTRUCTIONS
CAUTION: Disconnect pump from power source before
attempting to service or replace parts. Refer to the drawings
at the bottom of the page for all replacement instructions.
IMPELLER & WEAR PLATES: These parts are designed to
handle most clear, nonfl ammable liquids with slight amounts
of abrasives. When impeller vanes become worn from use,
or damaged due to pumping abrasive liquids or trash, pump
performance will be reduced or prevented altogether.
• Remove four cover plate screws and cover plate.
• Remove front metal wear plate. Inspect front metal wear
plate, impeller, back metal wear plate and O-ring for wear
or damage. If there is any evidence of wear or damage,
replace the part(s).
• Lubricate new impeller with white grease or lightweight
oil and reinstall by aligning fl at on impeller hub with fl at
on motor shaft. Reassemble metal wear plates, O-ring,
cover plate and cover plate screws.
Handle
Motor
Outlet
Rotation

PARTS LIST

SHAFT SEAL: Motor shafts are sealed with factory pre-
lubricated lip-type seals which are generally good for the
life of the pump. If the seal leaks, it is usually because the
pump has handled abrasive liquids. If the motor shaft is
scored (deep grooves), the complete pump must be replaced.
• Remove and inspect impeller parts as specifi ed in the
• Remove two pump body mounting screws and slide pump
• Lubricate new seal with lightweight oil, push it into pump
• Reassemble impeller parts into pump body. Slide pump body
MOTOR BRUSHES: Motor should be checked every 50 hours
of pump operation and replaced if worn. They must be
Impeller
replaced every 150 hours of pump operation. Service one
brush at a time.
• Remove brush cap.
Inlet
• Remove brush assembly (brass brush plate, spring, brush)
• Reinstall brush cap spring and rethread brush cap. Repeat
2
impeller replacement instructions. Replace worn parts.
body from motor. Pry out seal retaining ring and push
worn shaft seal from inside of pump body.
body with lip facing away from motor and push in seal
retaining ring.
onto motor shaft by aligning fl at on impeller hub with fl at on
motor shaft. Thread pump body mounting screws into motor.
and replace with new brush assembly.
steps for remaining brush.