Installation Instructions
RSWPD - Outdoor Sensor Extender/Multiplier
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be
performed by a qualified electrician. This product must be installed in accordance with the applicable installation code
by a person familiar with the construction and operation of the product and hazards involved. For continued protection
against shock hazard replace all covers and guards after field wiring is completed.
Risk of Fire and Electric Shock- Before installing or performing any service, the power MUST be turned OFF.
All installations should be in compliance with the National Electric Code and all state and local codes.
Risk of Burn- Disconnect power and allow product to cool before handling or servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise
from the improper, careless, or negligent installation, handling or use of this product.
IMPORTANT: Read carefully before installing product. Retain for future reference.
NOTICE: Product may become damaged and/or unstable if not installed properly.
Note: Specifications and dimensions subject to change without notice.
ATTENTION Receiving Department: Note actual product description of any shortage or noticeable damage on delivery receipt.
File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be filed within 15 days of delivery.
All damaged material, complete with original packing must be retained.
NOTE: These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to
provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is
desired to satisfy a problem not covered sufficiently for user's purpose, please contact your nearest representative.
NOTE: This fixture has been shipped complete with one of several mounting options. Please follow the installation instructions specific
to the catalog part that you ordered.
NOTE: Care must be taken not to set fixture down on optical lenses or lift the fixture in the lens area.
NOTE: Specifications and dimensions subject to change without notice.
NOTICE: All new wiring must be fully verified before applying power.
Do not mount luminaire within 6" of a combustible surface.
SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper
grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.
APPLICATIONS: The remote sensor housing incorporates a WaveLinx wireless sensor available with two alternate control options:
OPTION 1: Control Multiplier (CM) is a Wavelinx controlled relay to service an 8-amp to 16-amp load (depending on voltage). Power
monitoring is not available for this option. Dimming control is not available.
OPTION 2: Wireless Extender (WE) is a remote sensor housing that is a Wavelinx repeater or "hopper" . Line in power will only need to
be connected for the sensor to operate.
WaveLinx Wireless
WARNING

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Cooper Lighting RSWPD

  • Página 1 Failure to comply with these instructions may result in death, serious bodily injury and property damage. DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product.
  • Página 2: Tools Required

    WaveLinx Wireless RSWPD - Outdoor Sensor Extender/Multiplier INSTALLATION This lighting fixture has been shipped complete with one Collar side of several mounting options. Please follow the installation flush Shown with instructions specific to the catalog part that you ordered. tabs before...
  • Página 3: Wall Mounted

    WaveLinx Wireless RSWPD - Outdoor Sensor Extender/Multiplier Wall Mounted 2.2” [55.1mm] The housing can mount to a wall, mounting directly to a single No.6 gang wall box (Figure 5) for compatible box configuration. See Screws the wiring diagrams below for both configurations: •...
  • Página 4 WaveLinx Wireless RSWPD - Outdoor Sensor Extender/Multiplier Use Wire Nuts Suitable for the Lanyard Connecting Wire AWG Hook Tab HOT IN NEUTRAL HOT LOAD GND - Green NEUTRAL - Line White 12 AWG HOT IN - Line Black Housing Mounting...
  • Página 5 La désobéissance aux instructions suivantes représente un risque de blessures (y compris la mort) et de dommages matériels. EXONÉRATION DE RESPONSABILITÉ : Cooper Lighting Solutions n’assume aucune responsabilité pour les dommages ou pertes de quelque nature que ce soit pouvant découler d’une installation, d’une manipulation ou d’une utilisation inappropriée, imprudente ou négligente de ce produit.
  • Página 6 WaveLinx sans fil RSWPD - Prolongateur/multiplicateur pour capteur extérieur INSTALLATION Ce luminaire est livré avec toutes ses pièces et l’une des différentes options de montage. Veuillez suivre les instructions Collier affleurant d’installation se rapportant au modèle que vous avez Illustré avec les commandé.
  • Página 7 WaveLinx sans fil RSWPD - Prolongateur/multiplicateur pour capteur extérieur Installé au mur 55,12mm [2,2po] Le boîtier peut s’installer sur un mur, directement sur un boîtier mural standard (Figure 5) pour une configuration compatible. no 6 Consultez le schéma de câblage ci-dessous pour connaître les deux configurations: Prolongateur sans fil (Figure 6) ou multiplicateur de contrôle...
  • Página 8 WaveLinx sans fil RSWPD - Prolongateur/multiplicateur pour capteur extérieur Utilisez des capuchons de connexion Crochet appropriés au câble de connexion AWG de longe TERRE COURANT ALIMENTATION NEUTRE COURANT CHARGE TERRE - Vert NEUTRE - Ligne Blanche Vis de 12 AWG...
  • Página 9 El incumplimiento de estas instrucciones puede provocar lesiones graves (incluida la muerte) y daños a la propiedad. RENUNCIA DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o pérdidas de ningún tipo que puedan surgir por la instalación, manipulación o uso inadecuado, descuidado o negligente de este producto.
  • Página 10: Instalación

    WaveLinx Inalámbrico RSWPD - Prolongateur/multiplicateur pour capteur extérieur INSTALACIÓN Esta luminaria se ha enviado completa con una de varias opciones de montaje. Siga las instrucciones de instalación específicas para la pieza que haya solicitado del catálogo. Herramientas necesarias Lateral del...
  • Página 11: Montaje En Paredes

    WaveLinx Inalámbrico RSWPD - Prolongateur/multiplicateur pour capteur extérieur Montaje en paredes 2.2” [55.1mm] El alojamiento puede montarse a una pared, directamente Tornillos a una caja para pared de salida única (Figura 5.) con una N.º 6 configuración compatible para cajas. Consulte los diagramas de cableado siguientes para ver ambas configuraciones: Extensor inalámbrico (Figura 6) o Multiplicador de control...
  • Página 12: Conexión A Tierra

    WaveLinx Inalámbrico RSWPD - Prolongateur/multiplicateur pour capteur extérieur Utilice las tuercas para cables adecuadas Lengüeta del para la conexión del cable AWG gancho de amarre CONEXIÓN A TIERRA VIVO ENTRADA NEUTRO VIVO CARGA CONEXIÓN A TIERRA - Verde NEUTRO - Blanco Tensión...

Tabla de contenido