PROTECTION CHARACTERISTICS
Low voltage protection
The inverter will automatically turn off when the DC voltage is
below the required amount. The input voltage range is 11 – 14
volts. When the DC voltage is below 11 volts, the buzzer will
sound. When the DC voltage is below 10 volts, the inverter will
automatically turn off.
High voltage protection
The inverter will automatically turn off when the DC voltage is
above the required amount. The input voltage range is 11 – 14
volts. When the DC voltage is above 14 volts, the inverter will
automatically turn off.
Overcharge protection
The inverter will automatically turn off when the input charge is
higher than the required amount.
Short-circuit protection
The inverter will automatically turn off when a short-circuit
occurs.
Temperature protection
The temperature will become too high for the inverter when it is
in use for an extended period of time or when it is not well
ventilated. The inverter will automatically turn off when the
temperature reaches 65°C. If you need to use the inverter for
an extended period of time, the charge needs to be 80% of the
average. Also, make sure the inverter is well ventilated.
Restore button
You must press this button, after the protection systems is
activated. When you press it, the system will back to initial mode,
then you can continue using the inverter in a normal way.