GB
4.2
No spent mandrel discharge
Cause
Nosepiece (A) too small
Dirt inside head (B)
Spent mandrel container (H) full
Mandrel tube blocked
4.3
LED lights flashing
Cause
No battery
Blind riveting tool overloaded
(LED flashes slowly – 1 Hz)
Blind riveting tool blocked on return (LED
flashes fast – 2 Hz)
5.
Warranty
The applicable terms and conditions of guarantee shall apply and can be viewed under follow-
ing link: www.gesipa.com/agb
22
Remedy
Exchange according to table (see 2.4)
Clean (see 2.7)
Take off and empty
Remove blocked mandrel and check for free
ejection (see 2.6.2)
Remedy
Change battery (see 2.6.2)
Select rivet dimensions according to work
capacity (see 2.1, 2.6.2)
Unscrew steel head sleeve and remove
blockage (see 2.7)