Descargar Imprimir esta página

Fiap ProfiHeat Active Guia De Inicio Rapido página 3

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
FIAP ProfiHeat Active
GB
Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit prior to using it for the first
time. Adhere to the safety information for the correct and safe use of the unit. Please keep these
operating instructions in a safe place! Also hand over the operating instructions when passing the
unit on to a new owner. Ensure that all work with this unit is only carried out in accordance with these
instructions.
Intended Use
The series FIAP ProfiHeat Active is used to deice inside the pond. The FIAP pond heating can be
mounted only outdoors. Any other may damage this product; in addition, improper use may result in
serious hazards, such as short-circuiting, fire, electrical shock etc. The entire product must not be
modified or converted in any manner whatsoever!
Please be sure to observe the safety information at all times!
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and
in the case of misuse. If used for purposes other than that intended, our warranty and operating permit
will become null and void.
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (2004/108/EC) as well as the
low voltage directive (2006/95/EC). The following harmonised standards apply:
EN 55014-1, EN 55014-2, EN 60335-1, EN 60335-2-41, EN 60598-1, EN 60598-2-18, EN 61000-3-2,
EN 61000-3-3, EN 61558-2-6
Safety information
The company FIAP has built this unit according to the state of the art and the valid safety regulations.
Despite the above, hazards for persons and assets can emanate from this unit if it is used in an
improper manner or not in accordance with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who
cannot recognise possible danger or who are not familiar with these operating instructions, are
not permitted to use the unit. Hazards encountered by the combination of water and electricity.
The combination of water and electricity can lead to death or severe injury from electrocution, if the unit
is incorrectly connected or misused. Prior to reaching into the water, always disconnect the power
supply to all units used in the water.
Correct electrical installation
Electrical installations at garden ponds must meet the international and national regulations valid for
installers. Especially adhere to DIN VDE 0100 and DIN VDE 0702. Only use cabes admitted for
external use and meeting DIN VDE 0620. Ensure that the transformer is protected by a rated fault
current of max. 30 mA via a fault current protection device. Only connect the transformer when the
electrical data of the power supply is identical to that on the type plate. Only operate the transformer
when plugged into a correctly fitted socket. For your own safety, consult a qualified electrician when
you have questions or encounter problems.
Safe operation of the unit
Keep socket and power plug dry. Route the power cables so that damage is excluded. Do not carry or
pull the units by the connection cables. The power connection cables cannot be replaced. If the cable
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
5
www.fiap.com
FIAP ProfiHeat Active
is damaged, the entire unit has to be disposed of. Never open the unit or its attendant components,
unless this is explicitly mentioned in the operating instructions. Never carry out technical modifications
to the unit. Only use original spare parts and original accessories for the unit. Only have repairs carried
out by authorised customer service points.
Start-up
To raise the temperature of 1 m³ water in 1 hour by 1°C needs about 1.000 kcal. This formula is only
an indication, as the temperature also depends on surface area and any insulation that may be
present. FIAP ProfiHeat Active is fitted with an adjustable thermostat that can be regulated up to 40°C.
The heating element with the temperature probe, as well as the inside of the casing have been
manufactured out of high-quality stainless steel. FIAP ProfiHeat Active can be connected using pond
tubing (ø 25, 32 and 40 mm) or PVC tubing (ø 50 and 63 mm).
The FIAP ProfiHeat Active has 63 mm couplings for a glueable connection; glueable adapters to 50mm
are provided. When using PVC tubing ensure that there is no strain on the connection to the frogs. Cut
the tube connectors to the required length (or use the frogs) and twist these, as well al the rubber
sealing ring, into the 50 mm adapter by hand. Prevent any damage by only using the connectors and
frogs provided.
Ensure that the apparatus never runs dry. For this reason, always ensure that the FIAP
ProfiHeat Active is installed horizontally, with the inlet and outlet on top. This ensures that
there will always be water in the apparatus, even if the pump should fall out accidentally.
Connect the pump to the FIAP ProfiHeat Active and switch the pump on. Check the system for flow
and leakage. In case of leakage on the tube connectors, (never force them!) use a piece of Teflon tape
on the thread of the connection. Put the plug into the socket and set the thermostat to the desired
temperature. As soon as the set temperature has been reached, the light will go off.
Maintenance and cleaning
The FIAP ProfiHeat Active needs no maintenance. The manufacturer must always do any needed
repairs. The adjustable thermostat must never be opened. All guarantees expire once the thermostat
has been opened. The element may not be covered in lime scale or caked dirt. Ensure that the water is
free of lime and place a filter in front of the heating element. Prevent air getting into the system. If a
part of the element is not covered with water, this section can become over heated and cause the
element to burn out.
Storage/Over-wintering
Clean the device completely after the heating period and check it for damage. Store it in a dry place.
Disposal
Dispose of the unit in accordance with the national legal regulations.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
6
www.fiap.com

Publicidad

loading

Este manual también es adecuado para:

2782