Testing the functions
1
Fit the spray shield.
2
2
Check the status of the heating element of
the storage water heater: LED on control
panel lights up blue, heating element is set
to user detection (economy mode)
(factory setting).
The spray nozzle is automatically cleaned
before and after each shower procedure.
3
Press the shower button on the control
panel: The spray arm is extended, the
shower starts.
B1070-005 © 08-2015
966.102.00.0 (04)
1
4
3
4
Increase or decrease the spray intensity by
pressing the < – > / < + > buttons.
5
Wait 3 min. Press shower button again and
check whether shower water is at body
temperature.
ºC
Result
All functions of the control panel have been
checked.
If the storage or transport temperature
exceeds 45 °C, the thermal cut-out will be
tripped.
6
If water is cold, reset thermal cut-out.