Sears Kenmore 796.8138 Manual De Uso Y Cuidado página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONNECTING
ELECTRIC DRYERS (continued)
WARNING:
Connect the power cord to the terminal block. Connect
each power cord wire to the terminal block screw that
has the same colored wire. For example, connect the
black power cord wire to the terminal block screw
with the black wire. Failure to follow these instructions
may result in a short, overload, fire or death.
Four-Wire
Power Cord
o A 4-wire
connection is required for all
mobile and manufactured home installations,
as well as all new construction after
January 1, 1996.
• A UL-listed
strain
relief
is required.
• Use a 30-amp, 240-volt,
4-wire,
UL-listed power cord
with #10 AWG-minimum
copper conductor and closed
loop or forked terminals with upturned ends.
Terminal
Block
UL-Listed
Relief
UL-Listed
4 Wire
Power
Cord
_t
Remove the terminal
block access cover on the upper
back of the dryer.
_I
Install a UL-listed strain relief into the power cord
through-hole.
O
Thread a 30-amp,
240-volt,
4-wire, UL-listed power
cord with #10 AWG-minimum
copper conductor
through the strain relief.
(Black)
Green Ground
Neutral
Green Wire
Grounding
Power Cord
Wire
O
Transfer the neutral grounding wire from behind the
green ground screw to the center screw of the terminal
block.
O1 Attach the two hot leads (black and red) of the power
cord to the outer terminal block screws.
_t
Attach the power cord white neutral wire to the cen-
ter screw of the terminal block.
Attach the power cord ground wire to the green
ground screw.
_I
TIGHTEN ALL SCREWS SECURELY.
_I
Reinstall the terminal block access cover.
Grounding through
the neutral wire is prohibited for:
(1) new branch-circuit installations, (2) mobile homes,
(3) recreational vehicles, and (4) areas where local
codes prohibit grounding through the neutral wire.
Three-Wire
Power Cord
• A 3-wire connection is NOT permitted on
new construction after January 1, 1996.
• A UL-listed strain relief is required.
• Use a 30-amp,
240-volt,
3-wire, UL-listed
power cord
with #10 AWG-minimum
copper conductor
and closed
loop or forked terminals with upturned
ends.
Terminal
Block
UL-Listed
Strain Relief
UL-Listed
3 Wire
Power
Cord
_I
Remove the terminal block access cover on the upper
back of the dryer.
O1 Install a UL-listed strain relief into the power cord
through-hole.
_I
Thread a 30-amp,
240-volt,
3-wire, UL-listed power
cord with #10 AWG-minimum
copper conductor
through the strain relief.
Neutral
...... _ _
...... Grounding_
Hot _Neut_al
Hot
W,r_
(Black)
(White)
(Red !
Green G
]
External Ground Wire J
_'__'_x
O
Attach the two hot leads (black and red) of the
power cord to the outer terminal
block screws.
O
@
@
O
Attach the power cord neutral (white) wire to the center
terminal block screw.
Connect the external ground (if required by local
codes) to the green ground screw.
TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal
block access coven
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kenmore 796.9138

Tabla de contenido