PRECAUTIONS AND SAFETY
INSTRUCTIONS
The Vicair AllRounder O2 may only be used as
described in this manual. The use of this product
in any other way, is considered to be misuse.
Vicair B.V. cannot be held responsible for
damage caused by misuse, improper use or
negligence. Make sure that you read and
understand this manual completely.
Warning! Your tailbone and pelvic bones should
not touch the bottom of the cushion. Checking
for "bottoming out" should be done during first
use and after adjustments to the cushion filling.
Warning! Check your skin regularly for redness.
Especially during first use, with extra sensitive
skin and/or during extra rough use. These are all
factors that might affect your skin tolerances. If
redness occurs and does not disappear after 15
minutes, consult your therapist or technical
advisor.
Warning! Vicair B.V. recommends to adjust the
filling grade under the direct supervision of your
therapist or technical advisor.
Warning! Do not fasten waist strap or leg straps
too tightly. This may cause a reduction of blood
flow and/or discomfort.
Warning! Wear a life jacket when using the
Vicair AllRounder O2 during water sports
activities.
Warning! In case of soiling with body fluids, and
when transferring the product to another user,
the product must be disinfected to avoid cross
contamination.
Warning! Every three months, check the product
for wear and deflated cells. In case of serious
damage, or a large number of deflated cells, do
not continue to use the product. Consult your
dealer.
Caution! Do not use or leave the product close
to a naked flame or a high temperature heat
source.
Caution! Do not steam clean or autoclave the
4
product. The product cannot withstand
excessive heat or pressure. When the given
cleaning instructions are not followed, it is very
likely that the product will age more rapid.
Caution! Do not use aggressive or abrasive
cleaners, or sharp objects to clean the cushion.
INSTALLATION
Warning! Do not fasten waist strap or leg straps
too tightly. This may cause a reduction of blood
flow and/or discomfort.
Checking the size of the Vicair AllRounder O2
Measure the width of your hips to check if the
size of the Vicair AllRounder O2 matches the
size of your body. When seated, hold a tape
measure horizontally above the widest point of
your upper legs, closely against the front of your
hips. Do not follow your leg contours, keep the
tape measure straight. See Figure 1. Measure
from A to B (or B to A).
Width A to B is:
•
< 38 cm / < 15 inch = Vicair AllRounder O2
Size S (Small)
•
38 – 42,5 cm / 15- 16¾ inch = Vicair
AllRounder O2 Size M (Medium)
•
43 - 48 cm / 17¼ - 19 inch = Vicair
AllRounder O2 Size L (Large)
Figure 1
E N