• The voltage in direct polarization is displayed in mV, in inverted polarization the
LCD screen will display "1".
Range
Testing conditions
Accuracy
Direct pol. current 1mA
Approx. Direct polarization voltage
DC approx.
reading.
Inverted pol. voltage
2,8 VDC approx.
Open circuit approx.
Audible if the resistance is under
voltage 2,8 VDC
30 Ω.
Measuring audible continuity
1. Connect the red testing probe in "V/Ω" and the black testing probe in "COM".
2 Set the knob to 200 Ω.
3. If the resistance is less than 30 Ω the meter will sound.
4. If the circuit is open, the LCD screen will display "1", indicating over range.
5. If you use this function while the circuit is energized, the buzzer will sound to
warning you. Don´t worry about it, it won´t cause any damage.
Protection against overcharge: 250 VDC or AC rms.
11 11