ADJUSTING GAS VALVE MINIMUM SETTING (OVEN)
Important
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
dure has been carried out (see page 20). Be-
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Fully screw the injector.
6 - After making the setting, seal the screw
with paint.
7 - Replace the control panel (B) and the
knobs (A) on completion of the operation.
IT
ADJUSTING TOP BURNER PRIMARY AIR (4 KW)
GB
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
DE
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
FR
panel (B).
4 - Remove the screw (D).
5 - Set the burner mount (E) at a distance of
ES
17 mm, and tighten the screw (D).
6 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
English
fore making this adjustment, check that the
gas supply pressure is the same as the ra-
ted pressure for the type of gas in use (see
table at back of manual).
C
A C
B
C
A C
B
- 24 -
D
IDM-39617001600.tif
E
D
IDM-39617001900.tif