Pump WaterVISE, FloVISE
General information
It is important that this manual is read carefully by the user and the installer in order to ensure proper functioning and lifespan of
the pump. Pahlen pumps are manufactured in accordance with the applicable standard and certified by the third party.
If the product is used incorrectly, is not maintained adequately, or modified, there is a risk of damage to people or material.
Pahlen AB is not responsible for the damage caused due to incorrect installation, handling errors or inadequate maintenance.
Modification or change of the product must only be made after receiving the manufacturer's approval. Only use spare parts and
fittings approved by the manufacturer.
For Pahlen's standard pools, the pool water must not be aggressive, see the record water values below. Pahlen also has special
pumps developed to manage aggressive water. Contact the Pahlén Product support for more information.
Transport and season storage: Store the pump in a dry environment in a temperature as stable as possible (Great temperature
changes and moist environment can lead to corrosion damages on motor coils or metal parts).
Safety
• The pump must only be used within the limit values given on the pump type plate and motor rating plate.
• It must be installed in accordance with the applicable local laws and rules, and according to the electricity company guidelines.
• Make sure that the pump type plate and the motor rating plate are readable even after the installation.
• Do not use the pump without its protective housing. Touching live or moving parts can cause serious damage.
• Always check that the current to the pump is disconnected before commencing any work, service or maintenance of the pump.
• Make sure that the right dimension of pipe to and from the pump is used, see the table on the next page. This reduces the risk
of pressure drop, which can lead to cavitation damages on the pump's mechanical parts.
• If there is a freezing hazard, the pump must be disconnected and drained out to avoid frost damages.
Note!
The equipment can be used by children from and above 8 years, and people (including children) with disability, sensory or
mental capacity or who have lack of experience or knowledge, if they have received guidance or information on using the
equipment in a safe manner, and understand the imminent risks. Children must not play with the equipment.
Cleaning and maintenance must not be carried out by children without guidance.
Product description
The pump is intended for circulation of filtered water in pools with chlorine disinfection (organic, inorganic chlorine). Pahlén can
not guarantee the pump's lifespan and operational performance with other types of disinfection agents.
The pre-filter enclosure can be dismantled, which allows the inlet direction to be turned without affecting the pump's performance
This is provided to facilitate placing the pump in an area where the installation space is limited.
Funktion
Suction side (A) - the pump sucks water.
The water passes through the pre-filter (B), which has an
inner strainer bucket, and further into the pump housing.
The water is pumped/pressed further out of the pump
housing on the pressure side (D).
Discharge valves (E) are opened during the draining of
the pre-filter and pump housing.
The product is intended for the following water
values:
Total chlorine:
max 3.5 mg/l *
Chloride (salt) content: max 250 mg/l
PH-value:
7.2 - 7.6
Alkalinity:
60-120 mg/l (ppm)
Calcium hardness:
100-300 mg/l (ppm)
Iron:
max 0.1 mg/l*
Copper:
max 0.2 mg/l*
Manganese:
max 0.05 mg/l*
Phosphorous:
max 0.01 mg/l*
Nitrate:
max 50 mg/l*
The product guarantee does not apply outside these
values.
* According to SS-EN 16713-3 2016
C
Pump type plate
Motor rating
plate
Picture 1
F
8
ENGLISH
E
D
A
Suction side
B
Prefilter housing
C Pump housing
D Pressure side
E
Lock handle
F
Drain plug
A
B