IMPORTANT:
•
The pull-out strength of the anchor bolt shall be more than 5 times of the total weight of the
installed devices (including the camera body, ceiling mount bracket, anchor bolts, and all other
parts).
•
When the existing anchor bolt is used as an anchor bolt for connecting the safety wire, make
sure that the distance between the anchor bolt and camera mounting position is 1 m {3.28 feet}
or less.
Step 3
Secure the safety wire angle (accessory) to the
anchor bolt (for connecting the safety wire),
and connect the safety wire (accessory).
Mount a nut so that the safety wire angle is
q
secured on the anchor bolt.
Disconnect the safety wire from the safety
w
wire angle.
Engage the face marked
e
bolt.
Bend the face marked
r
Connect the safety wire to the safety wire
t
angle again.
Engage the nut from beneath, and secure
y
the safety wire angle with top and bottom
nuts.
Engage another nut from beneath to tighten
u
and secure the nut that was engaged from
beneath in y in a double nut fashion.
Anchor bolt
e Insert
w Disconnect
Safety wire
Mark q
Safety wire angle
* The nut is omitted in the illustration above.
8
q with the anchor
w.
Upper side
Mark w
r Bend
Lower
side
t Connect
<Image of safety wire connection>
Note:
•
When the existing anchor bolt that has been
installed is used for connecting the safety
wire, the use of 2 spacer nuts is helpful.
Spacer nuts
Safety wire
Spacer nuts
Safety wire angle
Existing anchor bolt