Precautions for installation
Panasonic assumes no responsibility for injuries or property damage resulting from fail-
ures arising out of improper installation or operation inconsistent with this documenta-
tion.
The installation should comply with local electrical code.
This product is designed to be used indoors.
This product is not operable outdoors.
Do not expose this product to direct sunlight for hours and do not install the product near a heater
or an air conditioner.
Otherwise, it may cause deformation, discoloration and malfunction. Keep this product away from
water and moisture.
Installation area for this product
•
Make sure that the installation area is strong enough to hold the total weight of the camera
assembly before installation.
•
The installation area shall have 210 mm {8-9/32 inches} or more space behind the ceiling.
210 mm {8-9/32 inches}
or more
•
The thickness of the ceiling board for installation can range between 9 mm {3/8 inches} and
40 mm {1-9/16 inches}.
Do not place this product in the following places:
•
Locations where it may get wet from rain or water splash (including under the eaves, etc.)
•
Locations where a chemical agent is used such as a swimming pool
•
Locations subject to moisture or oil smoke such as a kitchen
•
Locations that have a specific environment that is subject to an inflammable atmosphere or sol-
vents
•
Locations where a radiation, an X-ray, a strong radio wave or a strong magnetic field is gener-
ated
•
Locations where corrosive gas is produced, locations where it may be damaged by briny air such
as seashores
•
Locations where the temperature is not within the specified range (–10 °C to +55 °C {14 °F to
131 °F})
•
Locations subject to vibrations, such as on vehicles, marine vessels, or above product lines (This
product is not designed for onvehicle use.)
•
Locations subject to condensation as the result of severe changes in temperature
4
Ceiling board: between 9 mm {3/8 inches}
and 40 mm {1-9/16 inches}