LINE VOLTAGE
For Warranty Statement, Service Parts, Technical Support, or to
Register your product, please visit our website or call:
In the United States - NuTone.com 888-336-6151.
In Canada - NuTone.ca 877-896-1119
READ AND SAVE THESE INSTRUCTIONS
NuTone offers a chime mechanism that can be wired directly to 120V AC
line voltage inside a two-gang dual voltage junction box
SC200DV or equivalent box, minimum 3-in. deep, 20 cu. in.
Use the appropriate wiring directions that follow.
WIRING
Turn Off Power at Service Entrance Before Wiring this Chime.
ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH
LOCAL AND/OR NATIONAL ELECTRICAL CODE AS APPLICABLE.
Purpose of Control: Operating Control, Type 1 Action, Pollution
Degree 2, Impulse Voltage: 2500.
Construction of Control: Enclosed plastic, installed in a
voltage junction box.
ROUGH-IN WIRING
1. Install a
two-gang
dual voltage junction box (CARLON Model#
SC200DV or equivalent box, minimum 3-in. deep, 20 cu. in.
separately)
at desired location of door chime. Ensure junction box is
positioned properly to mount flush with the drywall.
2. Run 120 VAC to the line voltage side of the junction box.
3. For wired pushbuttons only: Run two conductor 18-22 gauge wire to
chime location. Note: Pushbutton wires MUST NOT be placed inside
the line voltage side of the junction box. Place low voltage wires
through the low voltage opening in the other side of
voltage junction box.
FINAL WIRING
1. Wire chime mechanism to 120 VAC line (black to black; white to
white). FIG 1
2. If wireless kinetic pushbutton is used, skip to step 5.
3. Press low voltage wires from front door pushbutton into the low
voltage terminal block locations F, and COM1
4. If rear door pushbutton is used press low voltage wires from rear
door pushbutton into the low voltage terminal block locations R,
and COM2.
5. Secure chime mechanism to two-gang dual voltage junction box
with provided four (4) #6-32 screws. FIG. 2
6. Install decorative cover by snapping it onto four posts on the
chime mechanism until it sits flush against the wall FIG. 3.
NOTE: Chime tone selectivity is not an option for wired
configuration. Wired default tones: front - "ding dong", rear - "ding".
WIRELESS PUSHBUTTON OPERATION
If kinetic button is used, the chime mechanism has two buttons
underneath the decorative cover used for wireless button pairing, and
tone selection.
To pair wireless kinetic buttons:
1. Remove the decorative cover on the chime mechanism
2. Press the LEARN button on the chime mechanism. The LED will be
ON , and the chime will sound BEEP BEEP. FIG 3
3. Press the kinetic button to pair.
4. There are 8 chime tones programmed on the unit. Press the TONE
button to hear each tone, the last played tone will be stored in
memory for the kinetic button. FIG 3
5. If a rear door kinetic button is also used, repeat steps 3 and 4.
Different tones may be selected for front and rear doors.
6. Press the LEARN button again to quit the LEARN mode, LED will
turn off.
7. Install the decorative cover back onto the chime mechanism. FIG 3
KINETIC BUTTON INSTALLATION
DOOR CHIME
1. To release the mounting plate push down tab on bottom of pushbutton while
pushing upwards on the body of the button. FIG. 4
2. Place mounting plate in the desired location near the door and secure
using provided two screws.
3. Align the two tabs on the back of the pushbutton with the slots in
mounting plate, and press down until it snaps in place.
120 VAC LINE IN
(CARLON Model#
- sold separately).
two-gang
dual
- sold
AJUSTE A PRESIÓN
two-gang
dual
Regulatory Information
The 99528969 Chime Mechanism, and PB340K Kinetic Pushbutton are certified to comply with
applicable FCC and IC rules and regulations governing RF and EMI emissions. Refer to 99528969,
and PB340K. This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) This device
must accept any interference received, including interference that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician to help.
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
ISED Compliance Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to
the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
Regulatory ID for PB340K Kinetic Pushbutton
FCC ID: LQP-WB028
IC: 2245A-WB028
NEUTRAL
REAR
DOOR
N
L
(if included)
LINE
VOLTAGE
COM 2
R
COM 1
F
LOW
FRONT
VOLTAGE
DOOR
CHIME
MECHANISM
FIG. 1
SNAP
EMBOÎTER
LEARN BUTTON
BOUTON APPRENDRE
BOTÓN DE APRENDIZAJE
TONE BUTTON
BOUTON TONALITÉ
BOTÓN DE TONO
FIG. 3
CARLON Model#
SC200DV or equivalent
box
(sold
separately)
FIG. 2
KINETIC
BUTTON
1
2
FIG. 4
99046096B