BS 28 Combi.book Seite 14 Montag, 25. Oktober 2010 11:20 11
Noise/Vibration Information
Measured values determined according to EN 60 745.
Typically the A-weighted noise levels of the machine
are: sound pressure level 90.5 dB (A); sound power
level 101.5 dB (A).
Wear hearing protection!
Overall vibrational value (vector sum of three direc-
tions) determined according to EN 60 745:
Impact drilling into concrete: Vibrational emission value
a
= 12.3 m/s
2
, uncertainty K = 1.5m/s
h
Drilling into metal: Vibrational emission value
a
<2.5 m/s
2
, uncertainty K = 1.5 m/s
h
Screwdriving: Vibrational emission value
a
< 2.5 m/s
2
, uncertainty K=1.5 m/s
h
The vibration emission level given in this information
sheet has been measured in accordance with a stand-
ardised test given in EN 60745 and may be used to
compare one tool with another. It may be used for a
preliminary assessment of the vibrational impact.
The declared vibration emission level represents the
main applications of the power tool. However if the
power tool is used for other applications, with different
accessories or poorly maintained, the vibration emis-
sion may differ. This may significantly increase the vi-
brational impact over the total working period.
An estimation of the level of exposure to vibration
should also take into account the times when the tool is
switched off or when it is running but not actually doing
the job. This may significantly reduce the exposure level
over the total working period.
Identify additional safety measures to protect the oper-
ator from the effects of vibration such as: Maintain the
power tool and the accessories, keep the hands warm,
organisation of work patterns.
14
We declare under our sole responsibility that this prod-
uct is in conformity with the following standards or
standardization documents: EN 60745, EN 55014-1,
EN 55014-2 according to the provisions of the regula-
tions 2006/42/EG, /EC, 2004/108/EC.
Technical file at:
Adolf Würth GmbH & Co. KG, Abt PFW
2
74650 Künzelsau
2
.
2
.
N. Heckmann
Chairman of
Adolf Würth
GmbH & Co. KG
Künzelsau: 02.09.2010
Subject to change without notice
Declaration of Conformity
A. Kräutle