TECHNICAL DATA
Measurement range: 0.05 - 60 meter
Accuracy: ± 1.5 mm
Unit of measurement: m / inch / feet
Battery type: AAA (x3)
Laser class: Class II
Laser wavelength: 630 - 670 nm
Laser power: < 1 mW
Operating temperature: -5 - 40C
Storage temperature: -20 - 60C
Weight: 125 g
Dimension: 120 x 51 x 29 mm
ATTENTION
Read the operating instructions and the included safety information carefully before using the product.
Use the product correctly, with caution and only for the intended purpose. Failure to observe the
safety instructions can lead to damage, injury and voiding of the warranty. Keep these instructions in
a safe and dry place for future reference. Include the operating instructions if you pass the product on
to third parties.
INTENDED USE
This product is used to measurement of lengths and calculate of areas, volume, height difference.
The product storage the measuring data and works according to two calculation method, direct
measuring and Pythagorean theorem.
SAFETY INFORMATIONS
Keep children and bystander away from the work area.
Do not allow children to play with this product or its packaging.
Make sure that the work area is adequately illuminated.
Keep the work area clean, tidy, dry and free of other materials.
Failure to use the instrument according to the operation method provided in this User Manual
may cause damage to the instrument, affect the measurement accuracy or lead to personal
injury.
Do not use this product in highly inflammable and explosive environments.
It is strictly prohibited to shine the laser of this instrument in your own or others eyes.
Place the product in an unreachable place for children.
Do not allow bystanders to use the product.
Do not repair the product by yourself. In case of any problem of the product, please contact us
to solve a problem at the first use.
REPLACING BATTERY
1. Open the battery cover at the back of the instrument, place the battery correctly according to the
polarity and close the battery cover.
2. Only use 1.5V AAA alkaline battery for this instrument.
3. Please take out the battery in case of not-use of the instrument for a long time to avoid corrosion
by battery.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Laser Distance Meter
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
BGS 8639
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed