10. Troubleshooting
10. Troubleshooting
Fault
Engine does not start
Generator has too little or no
voltage
11. Maintenance schedule
11. Maintenance schedule
Regular service period
month or operating hour
interval, whichever comes
ITEM
Engine oil
Check level
Change
Air cleaner
Check
Clean
Spark plug
Check-adjust
Replace
Spark arrester
Clean
Valve clearance Check-adjust
Combustion
chamber
Clean
Fuel tank and
Fuel tube
Check
Remark:
procedures.
Failure to follow this maintenance schedule could result in non-warrantable failures.
Cause
Oil shortage cut-out has not
responded
Spark plug fouled
No fuel
Battery voltage too low
Controller or capacitor defective
Overload cut-off has triggered
First
Each
month
use
or
20 Hrs.
O
O
O
Remedy
Check oil level, top up engine oil
Clean or replace spark plug
Charge the battery
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Every
Every
3
6
months
months
or
or
50 Hrs.
100 Hrs.
O
O
O
O
Every
year
or
200 Hrs.
13