1
Safety Guidelines
1.
Follow the installation instructions.
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 2 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety.
2
Technical Data
Media
Medium:
Connections/Sizes
Connection sizes:
Pressure values
Min. operating pressure:
Max. inlet pressure with clear
filter bowl:
Outlet pressure:
Operating temperatures
Max. operating temperature
medium accord. to EN 1567:
Specifications
Installation position:
Note:
The filter is constructed for drinking water installations. In
case of a process water application the filter has to be
proven individually.
3
Options
For Options visit homecomfort.resideo.com/europe
4
Assembly
4.1 Installation Guidelines
•
Install in horizontal pipework with filter bowl
downwards
– This position ensures optimum filter efficiency
•
Install shut-off valves
Drinking water
1
/
" - 2"
2
1.5 bar (dynamic pressure)
16 bar
1.5 - 6 bar
30 °C
Horizontal with filter bowl
downwards
GB
•
Ensure good access
– Pressure gauge can be read off easily
– Degree of contamination can be easily seen with
clear filter bowl
– Simplifies maintenance and inspection
•
The installation location should be protected against
frost
•
Related to the EN 806-2 it is recommended to install
the filter immediately after the water meter
•
In order to avoid flooding, it is recommended to
arrange a permanent, professionally dimensioned
wastewater connection
4.2 Assembly instructions
1.
Thoroughly flush pipework
2.
Fit filter combination
• Note flow direction
• Install without tension or bending stresses
3.
Seal in pressure gauges
4.
Set outlet pressure
4.3 Discharge of reverse rinsing water
The reverse rinsing water must be routed to the drain channel
in such a way that no backwater can occur.
To do this there are 3 options:
1.
Direct connection:
• Connector DN 50/70 as well as the necessary
pipes and siphon (3 elbows 90°) in DN 70.
2.
Discharge into floor drain
3.
Drain into open container.
Filter size
1/2" and 3/4"
1" and 1 1/4"
1 1/2" and 2"
*at 4 bar inlet pressure and 3 x 3 seconds reverse rinsing
duration
5
Start-up
5.1 Setting outlet pressure
Set outlet pressure min. 1 bar under inlet pressure.
1.
Close shut-off valve on inlet
2.
Release pressure on outlet side (e.g. through water
tap)
3.
Close shut-off valve on outlet
4.
Loosen slotted screw
• Do not remove slotted screw
5.
Slacken tension in compression spring
• Turn adjustment handle counter clockwise (-) until
it does not move any more
6.
Slowly open shut-off valve on inlet
7.
Turn control handle until the setting scale shows the
desired value
4
Reverse rinsing volume*
12 Liter
15 Liter
18 litres
MU1H-1130GE23 R0220