New Specifications
Output Capacity (VA/Watts):
Input Frequency
Battery Runtime (Half Load/
Full Load) Minutes:
Typical Runtime (Desktop
PC/15 in. monitor) Minutes:
Battery Recharge Time:
Dimensions (H x W x D):
Weight
Approvals:
The new OmniPro INT 300 shares all of the functions of the OmniSmart INT 280 in
the accompanying manual, with the following exceptions:
• The OmniPro INT 300 does not feature a DB9 serial port and does not include
PowerAlert Software or cabling.
• The OmniPro INT 300 has two diagnostic LEDs that indicate on-line and on-
battery status.
• The OmniPro INT 300 has no Alarm Mute/Test Switch.
• The OmniPro INT 300 features two IEC-320 AC output receptacles.
• The OmniPro INT 300 features a battery replacement door on the rear panel.
Under normal conditions, the original battery in the UPS system will last
between 3 and 6 years. Qualified service personnel should read and observe
all precautions listed below before attempting replacement.
Battery Replacement WARNINGS: Battery replacement should be performed by
qualified service personnel only. Disconnect UPS from wall receptacle before performing
battery replacement. Keep all other people away from the area when performing battery
replacement. The batteries contain lead and acid. Do not dispose of the batteries in a
fire. Do not open the batteries. Do not short or bridge the battery terminals with any
object. Do not touch the loose battery terminal wires together or to any metal part of the
UPS cabinet. Except for the replaceable battery, the UPS contains no user replaceable
parts. A battery can present a risk of electrical shock or burn from high short-circuit
current. Observe the following precautions while replacing batteries: 1) Remove
watches, rings and all other metal objects; 2) Use tools with insulated handles. After
removing UPS batteries, proper disposal is required. The batteries are recyclable. Refer
to your local codes for complete recycling information. When replacing batteries, use the
same number and type batteries originally installed in your UPS. Contact
customer support at (773) 869-1234 for further information on battery replacement.
Copyright © 2000
OmniPro INT 300
300/175
50/60 Hz
17/5
15
2-4 hours
21 x 10.8 x 14.6 cm
5 kg
UL, CE
. All rights reserved. OmniSmart
Owner's Manual Addendum to #93-1208
OmniPro
Line Interactive UPS System
220/240V, 50/60Hz
ESPAÑOL: p. 2
FRANÇAIS : p. 3
DEUTSCH: p. 4
™
™
and OmniPro
are trademarks of
™
INT 300
.