Read and saVe these instRuCtions
waRning
to ReduCe the Risk of fiRe, eleCtRiC shoCk, oR injuRy to
PeRsons, oBseRVe the following:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. This unit must be grounded.
Broan-nuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THere are
no oTHer WarranTIeS, eXPreSS or IMPLIeD, InCLuDInG, BuT noT LIMITeD To, IMPLIeD WarranTIeS oF MerCHanTaBILITY or FITneSS For a ParTICuLar PurPoSe.
During this one-year period, Broan-nuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WarranTY DoeS noT eXTenD To FLuoreSCenT LaMP STarTerS anD TuBeS. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse,
negligence, accident, improper maintenance or repair (other than by Broan-nuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not
apply to you.
Broan-nuTone'S oBLIGaTIon To rePaIr or rePLaCe, aT Broan-nuTone'S oPTIon, SHaLL Be THe PurCHaSer'S SoLe anD eXCLuSIVe reMeDY unDer THIS WarranTY. Broan-nuTone SHaLL noT Be LIaBLe For
InCIDenTaL, ConSeQuenTIaL or SPeCIaL DaMaGeS arISInG ouT oF or In ConneCTIon WITH ProDuCT uSe or PerForManCe. Some states do not allow the exclusion or limitation of incidental or consequential dam-
ages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-nuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or
part. at the time of requesting warranty service, you must present evidence of the original purchase date.
Broan-nuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
model smsCPlR
®
Broan-nuTone one Year LIMITeD WarranTY
installation
220V, 15A
DOUBLE-POLE
CIRCUIT BREAKER
BLACK
BLACK
RED
RED
GRD
GRD
WHITE
PHASE
COUPLER
CIRCUIT BREAKER PANEL
Install phase coupler and wire as shown. Use following
guidelines:
• Use minimum 75 °C rated electrical wiring.
• Specify deep device electrical boxes where controls will be
installed. These controls fit in most North American electrical
boxes; however, deep boxes provide extra working space which
eases installation. Labor cost savings can offset higher box
costs, which is usually less than a dollar over standard depth
boxes. Use boxes that have 18 cu. in. minimum volume and
are at least 1-1/2 in. deep.
• Phase coupler must be grounded using attached ground wire.
how Phase CouPleR woRks
Broan SmartSense
system is design to provide recommended
®
ventilation for desirable indoor air quality. Related ventilation
requirements of *ANSI/ASHRAE Standard 62, "Ventilation for
Acceptable Indoor Air Quality" are fulfilled when this system is
installed accordingly.
A single Broan SmartSense
ventilation rates for larger homes; however, it is recommended
to use multiple installations for homes with multiple bathrooms.
Multiple installations provide distributed ventilation throughout
the home.
Multiple installations communicate through a home's electrical
power circuits to form an indoor air quality network. The phase
coupler provides a communication bridge between a home's two
electrical phases. A phase coupler is required when multiple
Broan SmartSense
installations are connected on both electrical
®
power phases in a home.
* American National Standards Institute / American Society of Heating, Refrigerating
and Air-Conditioning Engineers
aPPly identifiCation laBel
Phase coupler is packaged with a label identical to one on its
face. Apply this label to outside of electrical box cover in order
to identify its contents.
LINE
Black
MAIN
GROUND
Bare
To
Copper
SWITCHES
and
VENTILATORS
15
15
NEUTRAL
GROUND BUS BAR
White
120VAC
system is powerful enough to fulfill
®
99044389B

Publicidad

loading

Resumen de contenidos para Broan SmartSense SMSCPLR

  • Página 1 This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-nuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.