Distance value reproducibility
Distance value-accuracy
Type of light
Light spot diameter/distance
Wavelength
Supply voltage
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
Enclosure rating
Protection class
Weight
Material, optics
Ambient operating temperature
Ambient temperature, storage
Warm-up time
Initialization time
UL file no.
IO-Link
Process data structure
1)
Object with 6 % ... 90 % remission (based on standard white DIN 5033)
2)
Adjustable
3)
Equivalent to 1 σ.
4)
See reproducibility characteristics.
5)
6% ... 90% remission (based on standard white DIN 5033)
Average life cycle: 100,000 h at T
6)
7)
Limit value; operation in short-circuit protection mains max. 8 A
8)
Must not fall below or exceed U
9)
Without load. For U
= 24 V.
V
10)
Signal transit time with resistive load
11)
With a light/dark ratio of 1:1.
12)
From T
= 45 °C a maximum output current I
U
13)
Under T
= -10 °C a warm-up time is necessary.
U
Table 5: Speed - Repeatability
8022570.1A3H / 25.11.2020 | SICK
Subject to change without notice
= +25 °C
U
tolerances.
B
= 50 mA is permitted.
max
TECHNICAL DATA
Speed
Distance
7,5 mm ... 13 mm
4,5 mm ... 11 mm
3) 4) 5)
Typ -10mm, +80mm
Laser
6)
Ø 4 mm (1000 mm)
Ø 4 mm (1000 mm)
658 nm
DC 10 ... 30 V
≤5 V
8)
PP
≤ 25 mA
≤ 50 mA
typ. 0.5 ms
typ. 5 ms
10)
1000 Hz
100 Hz
11)
IP67
III
10 g
Kunststoff, PMMA
-40 ... +50 °C
-40 ... +75 °C
< 10 min
13)
< 10 min
<300 ms
E181493
IO-Link V1.1
COM3 (38,4 kBaud)
Zykluszeit 0,8 ms
Prozessdatenlänge 4 Byte
Bit 0 ... 9: Bool
Bit 16 ... 31: UInt
10
3) 4) 5)
7)
9)
10)
11)
12)
13)