Safety Notes; Technical Data; Replacement Parts - Grohe 36 334 Manual De Instrucciones

Ocultar thumbs Ver también para 36 334:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7
GB

Safety notes

Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The switched-mode power supply is only suitable for
indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.

Technical data

• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (15 - 35 cm adjustable): 25 cm
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Power supply unit defective
- Power supply switched off
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filters in connection hose dirty
Mixing device
• See "Flow rate too low"
incorrect (36 336)
• Limescale on mixer spindle
Installation
, see fold-out page II.
Plaster and tile the wall, excluding the area of the
structural shell protection.
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
Temperature adjustment,
see fold-out page II.
Operation and settings,
see technical product information, 99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
4 W
approaching user.
60 s
Setting mode is automatically terminated after 3 minutes..
Maintenance
1 s
•Shut off hot and cold water supply.
•Disconnect voltage supply.
IP 59K
•Inspect and clean all components and replace if
necessary.

Replacement parts

A
2
see fold-out page I (* = special accessories)
2500 V
100 °C
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace power supply unit
- Switch on voltage supply
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Clean or replace mixer spindle
, see fold-out page II.