2
Installation
The proper location
• Install your machine in environments which
have no risk of freezing and in a stable and
level position.
• Do not place your machine on a long pile
rug or on similar surfaces.
• Operate your machine in a well ventilated,
dust-free environment.
B
Make sure that your machine is not placed
on the power cable.
B
Place it at least 3 cm away from the edges
of other furniture and the walls.
• A special part (Part no: 295 970 0100)
replacing the top trim must be provided and
installed by the Authorized Service in order
to use the machine under a counter or in
a cupboard. It should never be operated
without the top trim.
• Place the machine on a sound floor. If it is
to be placed on top of a washing machine,
the approximate weight together may reach
180 kg when they are full.
• A fitting device should be used between
the two machines for use on a washing
machine. The fitting device (Part no 296
280 0100 white/ 296 280 0200 grey ) must
be installed by the Authorized Service.
Levelling
In order to ensure that your
machine operates more
silently and vibration-free, it
must stand level and balanced
on its feet. Front feet of your
machine can be adjusted.
Balance the machine by
adjusting the feet.
Loosen the feet by hand. Adjust them until the
machine stands level and firm.
C
Never unscrew the adjustable feet from
their housings.
2 plastic pieces supplied together with the
Operating Instructions prevent your machine
from slipping on wet and slippery surfaces.
Tilt your machine to backwards t install these
plastic parts. Fit the plastic parts to the front
adjustable feet. Press on the plastic parts to
fix them in their places. Check the balance
of your machine again and readjust the
adjustable feet if necessary.
Ventilation hose and connection (for
products equipped with an outlet
vent)
Ventilation hose assures exhausting of the air
from inside the machine. Vented dryer has 1
air outlet. Stainless sheet metal or aluminum
pipes can be used instead of the hose. The
diameter of the pipe to be used should be
minimum 10 cm.
Maximum hose and pipe lengths are given in
the table below.
Maximum length
1 elbow 45°
1 elbow 90°
1 elbow 90° short
1 wall passage
Each elbow and other passages should be
subtracted from the above maximum
length.
Connect the air outlet hose to the hose spacer
piece by turning it anti-clockwise in order
to connect the ventilation hose. Make the
hose passages as shown below.
C
Exhaust of humid air from the dryer into the
room is inconvenient. Air outlet hose must
be extended directly to the outdoors. There
must be a small number of elbows as not to
hinder air ventilation.
C
The ventilation hose can be routed
outdoors via a window or it can be
connected to the air outlet in the bathroom.
C
To prevent water accumulation in the hose,
make sure that it is not folded on the floor.
A
The air ventilation hose should not be
connected to the chimney of a stove or a
fireplace.
A
Pay attention that the air inlet openings are
unobstructed.
A
Do not operate your machine at the same
time with heaters such as a coal or gas
stove. Airflow may cause the chimney to
flare up. Airflow may cause the chimney to
flame up.
5 - EN
Hose
Pipe
4 m
5 m
-1.0 m
-0.3 m
-1.8 m
-0.6 m
-2.7 m
-2.0 m
-2.0 m