Technical Data - REV Ritter HFGT400ABWM Indicación Para El Montaje Y El Servicio

Reflector de halógeno sensor de movimientos 150/500w ip44
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 8
GB
MOTION DETECTOR – GENERAL INFORMATION
• The motion detector uses passive infrared technology. .
• Highly sensitive infrared detectors react to minute temperature changes in the coverage
area, e.g. those caused by a human being.
• Trees and shrubs can trigger false readings – the ideal installation height is 2.5m.
• The range and sensitivity depends on the ambient temperature; for example, the range
can increase in cool weather.
• While the motion detector is protected against the weather, an additional enclosure is
recommended.

TECHNICAL DATA

• Output:
HFGT120ABWM
HFGT400ABWM
• Voltage:
230V~, 50Hz
• Acquisition angle:
110°/180°
• adjustable vertically and horizontally
• Range max:
12m
• Response time:
8 sec.– 12 min
• Twilight controller:
Adjustable
• Protection class:
IP44
• Replacement illuminant:
Art.-Nr. 0599940555/120W
R7S
Art.-Nr. 0599950555/400W
ILLUMINANT INSTALLATION
• Loosen the screw on the top of the floodlight and swing the lens forward.
• Remove the illuminant from the packaging.
• Avoid touching it with bare hands since this causes grease stains which lead to
overheating. Use a clean, dry, lint-free cloth.
• Insert one end of the illuminant into the socket, press against it, and insert the other end
of the illuminant into the socket. Ensure that the socket is not damaged.
• Then close the lens and retighten the screw.
INSTALLING
Installation may only be carried out by trained professionals according to the applicable
installation regulations. Contact a licensed electrician.
ATTENTION!! Before installation, the power supply must be disconnected and locked out.
• Loosen the screws on the side of the housing and remove the mounting brackets.
• Install the mounting brackets to a suitable surface – always follow the installation
location requirements listed under "General Safety Information" (s. 1-4).
• Reattach the floodlight housing to the mounting brackets but do not tighten the screws
fully.
• Loosen the screws on the back of the junction box and remove the cover.
• Loosen the cable grip screws and remove the cable grip.
• Guide the screw connection seal over the cable as well, and then insert the cable
into the junction box. Ensure the seal is seated in the cable guide correctly – if the
8
max. 150W, 110°
max. 500W, 180°
connecting cable is too thin, the cable guide must be additionally sealed.
• Connect the wires according to Figure 5.
• Tighten the cable guide screw connection, install the cable grip, and tighten the screws.
• Install the junction box cover and tighten the screws.
SETTING THE FLOODLIGHT DIRECTION
• Loosen the screws on the sides of the mounting brackets, adjust the floodlight direction,
and then retighten all screws.
SETTING UP THE MOTION DETECTOR
• Turn both dials fully counter-clockwise (T). The floodlight turns on for approx. 1 minute
and then turns off.
• Walk the entire acquisition area. Once you leave the area, the halogen floodlight is
turned off after a time delay; upon re-entering the acquisition area, it is turned back on.
• The motion detector light sensitivity and activation time can be individually adjusted
using the dials.
REPLACING THE ILLUMINANT
You can find the technical data for the illuminant under "Technical Date" or on the type
plate attached to the floodlight housing.
• Disconnect and lock out the power supply to the floodlight. Allow the floodlight to cool
down sufficiently!
• Loosen the screw on the top of the floodlight and swing the lens forward.
• Loosen the wing nuts on top of the floodlight and swing the lens forward.
• Avoid touching it with bare hands since this causes grease stains which lead to
overheating. Use a clean, dry, lint-free cloth.
• Insert one end of the illuminant into the socket, press against it, and insert the other end
of the illuminant into the socket. Ensure that the socket is not damaged.
• Then close the lens and retighten the screw.
CLEANING
• Disconnect and lock out the power supply to the floodlight. Allow the floodlight to cool
down sufficiently!
• Clean with a dry or slightly moist, clean, lint-free cloth and a mild detergent if required.
Do not use cleaners that contain abrasives or solvents.
• If required, the illuminant can be cleaned with a lint-free cloth moistened with ethyl
alcohol. ATTENTION! After cleaning the illuminant with ethyl alcohol, it must be allowed
to air dry for at least 20 minutes.
MAINTENANCE
• If the lens is damaged it must be replaced immediately.
• Clean any dirt from the housing or the lens immediately, since it could cause
overheating.
GB
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hfgt120abwm

Tabla de contenido