Inspection And Maintenance - Hoshizaki FM-1200ALKE Manual De Instrucciones

Ocultar thumbs Ver también para FM-1200ALKE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
III. MAINTENANCE
1. CLEANING
WARNING
1. B e f o r e c a r r y i n g o u t a n y c l e a n i n g o r
maintenance operations, disconnect
the icemaker from the electrical supply
network.
2. Ask a trained service person to check and
clean the condenser at least once a year.
3. This appliance must not be cleaned by use
of a water jet.
4. To prevent possible damage, do not clean
the plastic parts with water above 40°C or
in a dishwasher.
[1] Machine and Bin Exterior
Wipe the exterior at least once per week with a
clean, soft cloth. Use a damp cloth containing a
neutral cleaner to wipe off grease or dirt.
[2] Scoop Cleaning/Sanitisation (Daily)
1) Either mix 1 litre of water with 4 ml of 5.25%
sodium hypochlorite solution in a suitable
container, or the recommended Hoshizaki
sanitiser as directed.
2) Soak the scoop in the solution for more than 3
minutes. Rinse thoroughly, and shake to remove
surplus liquid.
Note: Using a cloth to dry may re-contaminate.
[3] Storage Bin Interior Cleaning/Sanitisation
(Weekly)
1) Open the storage bin door, and remove all ice.
2) Remove the thumbscrews securing the baffle.
3) Remove the baffle from the bin.
4) Wash the bin liner and baffle with a neutral non-
abrasive cleaner. Rinse thoroughly.
5) Either mix 5 litres of water with 18 ml of 5.25%
sodium hypochlorite solution in a suitable
container, or the recommended Hoshizaki
sanitiser as directed.
6) Soak a clean sponge or cloth with the solution
and wipe the bin liner surfaces and baffle.
7) Refit the baffle and thumbscrews. Wipe the
surface of the bin door and thumbscrews with
the solution. Close the bin door.
8) The remaining solution can be used to sanitise
utensils.
Note: Do not wipe dry or rinse after sanitising, but
allow to air dry.
[4] Storage Bin Door
Clean the storage bin door at least once a week,
using a neutral non-abrasive cleaner. Rinse
thoroughly after cleaning and sanitise as required.

2. INSPECTION AND MAINTENANCE

IMPORTANT
To achieve optimum icemaker performance,
the following parts need periodic inspection
and maintenance:
Extruding head (upper bearing)
Housing (lower bearing)
Mechanical seal
These parts should be inspected after two
years from installation or 10,000 hours of
operation, whichever comes first, and once
a year thereafter. Replacement of these
parts is required if wear exceeds factory
recommendations.
Their service life, however, depends on
w a t e r q u a l i t y a n d e n v i r o n m e n t . M o r e
frequent inspection and maintenance are
r e c o m m e n d e d i n b a d o r s e v e r e w a t e r
conditions.
Consult with your local Hoshizaki service
agent about inspection and maintenance
service.
3. SERVICE CALL
WARNING
Do not damage the refrigerant circuit.
[1] Error Code Indication
If the error code "E" is indicated on the display,
before calling for service, check the following.
5
ENGLISH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fm-1200alke-nFm-1800alkeFm-1800alke-n

Tabla de contenido