Heater type
Models VHIS200
& VHIS300
Yoke bar 80
Bearing
229750/03
Model VHIN550
Yoke bar 100
Bearing RH24B
Model VHIN800
Yoke bar 150
Bearing 17.52926
Heights are measured from the bottom of the heater.To determine where
the field is exactly in relation to the floor, the distance from the bottom of
the heater to the floor should be added on to the values mentioned in the
table. (e.g. the height of a workbench).
WARNING!
• We advise a safety distance of at least 1 metre for people.
CAUTION!
• The machine works through an induction field. Bear in mind
that this can influence electronic equipment, e.g. watches,
magnetic charts etc.
2.
Application
Timken Induction Heaters are designed to heat bearings, bushings, gear
wheels, couplings or other metallic work pieces which form a closed electri-
cal loop.This will facilitate mounting where an interference fit is required.
noticeheaterGB.indd 7
Radius/
h = 900 mm
height*
(10in)
R = 250 mm
5,800 mT
R = 500 mm
1,070 mT
R = 750 mm
0,345 mT
R = 1000 mm
0,121 mT
R = 1250 mm
0,030 mT
R = 250 mm
6,400 mT
R = 500 mm
1,308 mT
R = 750 mm
0,350 mT
R = 1000 mm
0,116 mT
R = 1250 mm
0,030 mT
R = 500 mm
1,980 mT
R =
50 mm
0,530 mT
R = 1000 mm
0,180 mT
R = 1250 mm
0,070 mT
R = 1500 mm
0,020 mT
R = 1750 mm
0 mT

Introduction

7
h=1300 mm
h=1500 mm
(51in)
(59in)
0,750 mT
0,253 mT
0,320 mT
0,134 mT
0,141 mT
0,068 mT
0,054 mT
0,020 mT
0,006 mT
0 mT
4,100 mT
1,460 mT
1,050 mT
0,530 mT
0,298 mT
0,186 mT
0,093 mT
0,063 mT
0,017 mT
0,010 mT
1,375 mT
1,020 mT
0,450 mT
0,370 mT
0,180 mT
0,160 mT
0,030 mT
0,030 mT
0,020 mT
0,010 mT
0 mT
0 mT
GB
h =2000 mm
(79in)
0,010 mT
0 mT
0 mT
0 mT
0 mT
0,150 mT
0,105 mT
0,037 mT
0,010 mT
0 mT
0,340 mT
0,170 mT
0,080 mT
0,030 mT
0 mT
0 mT