Functions
The system can be put into operation once the
mains power has been connected and the unit
is closed. Two setting options are concealed
behind the decorative faceplate.
Pressing a programming button sets the
sensor to programming mode.
This means:
- The lamp connected always goes out
- Sensor function is deactivated
Twilight setting (response threshold)
(factory setting:
daylight operation
2000 lux)
2 – 2000 lux
The sensor's response threshold can be set
to between approx. 2 lux and 2000 lux.
Time setting (switch OFF delay)
(factory setting:
approx. 5 sec.)
5 sec. - 15 min.
The ON time can be varied continuously
between approx. 5 sec. and a maximum of
15 min.
a) Setting ON time to the accuracy of one
second
- Keep button
pressed until red LED flashes
(in the lens).
- Release button
and wait until chosen ON
time is shown (LED flashes).
- Press button
again until LED goes out.
Your chosen time is now stored to the
accuracy of a second.
- This process is terminated automatically
after the maximum selectable time (15 min.).

Reset function

All settings can be returned to their original
levels (daylight operation 2000 lux, ON dur-
ation 5 seconds) whenever you wish.
25.07.2008
15:09 Uhr
- Manual override function (if active) is can-
celled
The settings may be altered as often as you
wish. The last setting will remain stored in the
memory in the event of power failure.
Important: Only select time and twilight
setting with the lens in place.
a) Selecting twilight setting of your choice:
At the light level at which you now want the
sensor to respond to movement and switch on
light, press the button
flashes (in the lens). This light level will now be
stored.
Important: When setting, do not cover the lens
or shade it with your own shadow.
b) Setting night-time operation (4 lux) during
the day
Keep the button
pressed for approx. 5 sec-
onds until the red LED stops flashing in the lens.
- To select the shortest time setting, press
button
twice in brief succession.
b) Setting ON time to the accuracy of one
minute
- Keep button
pressed until red LED
flashes (in the lens).
- Release button
, now keep button
pressed until LED goes out and (after 3 sec.)
starts to flash again (slower).
- After the chosen number of flashes (each
LED flash equals 1 minute of light ON time),
re-press button
Your chosen time is now stored to the
accuracy of a minute.
- This process is terminated automatically
after the maximum number of flashes
(15 times = 15 min.).
c) Pulse function
The pulse function activates the output for
2 sec. (e.g. for staircase lighting time switches).
To do this, keep button
for approx. 5 sec. until the red LED stops
flashing.
To do this, keep both buttons pressed simul-
taneously until the LED (in the lens) comes on
and goes out again (approx. 5 seconds).