Descargar Imprimir esta página

Kohler K-1244-FH Diagrama De Instalación página 2

Bañera de hidromasaje en esquina

Publicidad

Idiomas disponibles

Idiomas disponibles

63-1/2" (161.3 cm)
36-5/8" (93 cm)
36-5/8"
(93 cm)
60"
(152.4 cm)
30" (76.2 cm)
1-1/4" (3.2 cm)
Product Information
Applicable product:
Integral tile flange, left-hand pump
Drop-in, left-hand pump
Fixture*:
Bathing well:
Basin area, bottom
50" (127 cm) x 42" (106.7 cm)
Basin area, top
60" (152.4 cm) x 46" (116.8 cm)
Weight
123 lbs (55.8 kg)
To overflow:
Water depth
14-1/2" (36.8 cm)
Capacity
102 gal (368.1 L)
* Approximate measurements for comparison only.
Included components:
Cut-out template, top
Cut-out template, bottom
Pump:
1-speed
Heater:
1.5 kW
Recommended accessories:
Pop-up drain
1013708-1-B
4-7/8"
(12.4 cm)
11-3/4"
(29.8 cm)
42-1/2" (108 cm)
60" (152.4 cm)
2-7/8" (7.3 cm)
3" (7.6 cm)
K-1244-FH
K-1244-H
1000550-7
1000551-7
V
Hz
A
120
60
7.5
120
60
12.5
K-7161-AF
No change in measurements if connected with
drain illustrated. (K-7161-AF or K-7161M-AF)
Recommended Faucet Area
30"
58"
(76.2 cm)
(147.3 cm)
Pump/Control Access Either Location
(If Apron Is Not Used)
20" (50.8 cm) W x 15" (38.1 cm) H
3-1/2"
(8.9 cm)
19-1/2"
21"
(49.5 cm)
(53.3 cm)
1-1/2" OD
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Heater
Locate the outlets behind the whirlpool and within 24" (61 cm)
of the pump and heater.
Notes
Install this product according to the installation guide.
Floor support under this product must provide for a minimum of
40 lbs/square foot (194 kg/square meter) loading.
The apron must be installed before the finished floor and wall
materials are installed.
If installing a rim-mount faucet, make sure there is no interference
with the drain overflow and circulating system before drilling any
holes. Consult local and national codes for minimum air gap
requirements if installing a spout on the faucet deck.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions
are nominal.
2
45˚
45˚
43-7/8"
(111.4 cm)
27" (68.6 cm)
Drop-in Rim Style
Cut-out Detail
1-1/4"
(3.2 cm)
1/2" (1.3 cm)
R. Max
Integral Flange
Detail
1-1/2"
(3.8 cm)
Drop-in Rim
Detail
120 V, 15 A, 60 Hz
120 V, 15 A, 60 Hz
Kohler Co.

Publicidad

loading

Este manual también es adecuado para:

K-1244-h