Press the cap (27 Fig. 10) towards the
boiler and unscrew and remove it.
-
Pour in the boiler about 3 liters of water.
-
Refit the cap (27 Fig. 10) by screwing un-
til the knob turns idle then press the cap
and rotate it 1/4 clockwise.
NOTE:
It is advisable to fill the tank with 50% tap
water and 50% de-mineralized water or alter-
natively demineralized water.
This is to prevent the formation of limescale
in the boiler.
USE OF THE APPLIANCE
Controls and Indicators (Fig. 11)
28) "White" indicator- minimum water lev-
el in the tank (if present)
It lights up when the water level in the
tank has reached a minimum level; re-fill
the tank as described in the relevant sec-
tion.
29) "Red" indicator- minimum water level
in the boiler
It lights up when the water level in the
boiler has reached the minimum level; the
lighting of the warning light switches off the
heating element operation by blocking the
water heater.
Fill the boiler and / or the tank as described
in the relevant paragraphs.
30) "Green" indicator- working tempera-
ture has been reached
Lights when the temperature inside the
boiler has reached the set value.
31) "Orange" indicator- line inserted (220V)
Lights when power supply is present; the
switch (32) pressed on "I" and enlight-
ened.
32) General switch
Main line switch, pressed on "I" lights up
and turns on the unit.
Pressed on "0" turns off and shuts off
power to the unit.
33) Resistor switch
Pressed on "I" inserts electrical supply for
heating water; during the water heating
the switch is lit and when reaching the set
temperature the switch turns off and the
warning light (30) turns on.
To disconnect the electrical supply press
the switch to "0".
34) Vacuum switch
Pressed on "I", with the line switch on, it
starts the operation of the vacuum clean-
er, pressed "0" stops the operation of the
vacuum cleaner.
35) Steam lever
Pressed while the machine is running
and the resistor switch is on, it delivers
steam.
NOTE:
It is possible, using the pin (36 Fig. 11),t o
lock the operation of the lever (35 Fig. 11) so
as not to deliver steam in an accidental way.
Filters position control
-
Release the levers (37 Fig. 12) and lift the
cylinder head (38 Fig. 13) and check that
you have two filters (39 and 40 Fig. 13).
-
Replace the cylinder head (38 Fig. 13) and
attach the levers (37 Fig. 12).
Use
-
The device is equipped with wheels and
then during use it can be moved through
the upper handle (58 Fig. 16).
WARNING:
Do not pull the machine by the hose.
-
To lift it up, insert your fingers under the
handle (41 Fig. 14) on the top of the cov-
er.
Starting the machine
-
Insert the plug (42 Fig. 15) into the electri-
cal socket.
-
Press the switch (32 Fig. 11) to "I" to turn
on the unit; the switch (32 Fig. 11) and the
led (31 Fig. 11) light.
-
Check that the plug (32a Fig. 11) is cor-
rectly inserted into the socket.
ENGLISH - 4
www.ghibliwirbel.com
Professional Cleaning Machines Since 1968