Address Switch Settings; Backbox Module Mounting - Bosch AutoDome Serie Instructions

Ocultar thumbs Ver también para AutoDome Serie:
Tabla de contenido

Publicidad

EN
4. Cut a hole in the tile using the bracket as a
template (FIGURE 6).
Figure 6 Cutting the Tile
5. Secure the bracket assembly to an overhead
securing point using a safety cable (FIGURE 7).
Figure 7 Safety Cable Fitment
4.4 Address and Dip Switch Settings
Before installing the backbox, set the Address and S105
switches (FIGURE 8). Setting the Address switch to 0000
(NOT RECOMMENDED) responds to all messages
regardless of address; otherwise, the unit will only respond
to commands issued for that address.
© 2003 Bosch Security Systems
The following dip switch settings pertain to AutoDome
Versions 5.00 and newer.
Switch # Function
Boot Mode Baud Rate
**1
(Firmware download only)
2
Serial Mode Selection
3
Camera Mode Selection
4
Low Pressure Detection
*Default position for all switch settings is OFF.
**Switch 1 Baud Rate only applies to a special mode to
download new firmware.
S105 Dip Switch
Figure 8 S105 Dip Switch and Address Switch

4.5 Backbox Module Mounting

Mount the backbox into the installed bracket assembly as
follows.
1. Verify that the edge of the hole will support the unit.
If the edge is uneven or slightly too large, attach the
appropriately colored (white/black) mounting ring, as
shown in FIGURE 9 and FIGURE 10. If the backbox
fits correctly, go directly to SECTION 4.6.
Figure 9 Mounting Ring Fitment
Installation
Position
Selection
ON
19.2K
OFF
57.6K*
ON
RS-485
OFF
RS-232*
ON
Boot Loader Mode
OFF
Normal Mode*
ON
Pressurized Dome
OFF
Non-Pressurized
Dome*
Address Switch
Page 9 of 16