Do not use damaged batteries. Ensure that they are correctly disposed of
(please see Chapter 6. STORAGE Disposal / Disposal of the batteries ).
Keep damaged batteries out of the reach of children.
The product will become hot when exposed to sunlight. Touching the
product in such a condition can result in slight burns if touched.
Batteries:
To ensure the Sensor runs safely, only 2 x alkalimanganese (alkaline)
batteries type LR6 (AA) (Mignon) must be used.
2. FUNCTION
With the GARDENA Soil Moisture Sensor the soil moisture level is taken into
consideration for watering. Depending on the soil moisture, measurements
are taken at intervals of between 30 and 60 minutes and sent to the irrigation
control.

3. INITIAL OPERATION

To insert the batteries [ Fig. I1 / I2 / I3 / I4 ]:
The batteries are not included in the scope of delivery.
The Sensor must only be operated with 2 x alkalimanganese (alkaline)
batteries type LR6 (AA) (Mignon).
The battery life is approx. 1 year. Depending on the outside temperature and
the frequency of measurement and transmission, the battery life may vary.
CAUTION!
Rechargeable batteries should not be used!
1867-20.960.01.indb 13
DANGER!
There is a risk of explosion if batteries are not replaced in the proper
manner. See 6. STORAGE for information on how to dispose of used
batteries.
To prevent failure of the Sensor due to weak batteries in conjunction
with a lengthy absence, batteries should be replaced in due course.
This will depend on the previous operating life of the batteries and the
probable length of absence, which should not exceed 6 month in total.
If the batteries are flat and are not replaced, the connected Irrigation control
will function with the watering program selected.
(1)
1. Pull the cover
upwards.
2. Insert the batteries (2 x alkaline type LR6 (AA))
(3)
compartment
. Make sure that the polarity is correct.
The LED battery
(4)
in the battery compartment
illuminates green for 3 seconds.
(1)
3. Close the cover
again.
If the LED battery
(4)
flashes red every 5 seconds, the batteries are empty
and must be replaced.
(4)
If the LED battery
illuminates red, an error has occurred
(see 7. TROUBLESHOOTING).
(2)
into the battery
(3)
below the bat teries 
(2)