LO is displayed
HI is displayed
E1, E2 is displayed
Resetting the thermostat (default settings)
NOTE: All parameters, except the clock (time and day), return to their default
settings when the thermostat is reset.
1. Press the Mode button until Standby appears on the screen.
2. Press the
button for 6 seconds.
3. The thermostat will display rSt (reset) for 2 seconds to indicate it is reset
and will then return to normal display.
Power outage
During a power outage, the thermostat display remains lit for the first 2
minutes. During this time, the LP (low power) indicator appears and all
buttons are disabled. Then the screen turns blank. The settings are stored
in memory. When power returns, the thermostat returns to the mode of
operation preceding the power outage. If the power failure has exceeded 5
hours, the clock and date must be re-adjusted.
Specifications
Supply: 120/240 VAC, 60 Hz
Minimum load: 0.83 A (resistive only)
Maximum load: 14.6 A (resistive only)
Display range: 32 °F to 99 °F (0 °C to 50.0 °C)
Setpoint range: 41 °F to 86 °F (5.0 °C to 30.0 °C)
Resolution: 1 °F (0.5 °C)
Storage temperature: -4 °F to 120 °F (-20 °C to 50 °C)
The measured temperature is below the display range. Heating is
activated.
The measured temperature is above the display range.
The thermostat performance is reduced due to a sensor error. Please
contact technical support for more information.
200 W @ 240 V AC
100 W @ 120 V AC
3500 W @ 240 V AC
1750 W @ 120 V AC