TECHNICAL DATA
BATTERY CHARGER
Voltage range ...................................................................................... 28 V
Quick charge current .......................................................................... 3.5 A
Battery charging time ............................................................... approx. 1 h
Weight according EPTA-Procedure 01/2003 ..................................... 700 g
Recommended ambient charging temperature .......................... +5...+40 °C
WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors off er to
retrieve old batteries to protect our environment.
Only the following battery packs can be charged with this
charger:
voltage
battery
rating
No. of
(of storage battery)
battery
cells
28 V
M28 BX
≤ 3.0 Ah
2 x 7
28 V
M28 B5
≤ 5.0 Ah
2 x 7
Do not try to charge non-rechargeable batteries with this
charger.
Do not store the battery pack together with metal objects
(short circuit risk).
No metal parts must be allowed to enter the battery section
of the charger (short circuit risk).
Never break open battery packs or chargers and store only
in dry rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains
supply. Do not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new
one.
Before use check machine, cable, and plug for any
damages or material fatigue. Repairs should only be carried
out by authorised Service Agents.
This appliance is not intended to
be used or cleaned by persons
with reduced physical, sensory or
mental capabilities, or lack of
experience or knowledge, unless
they have been given instructions
concerning the safe use of the
appliance by a person legally
responsible for their safety. They
should be supervised whilst using
the appliance. Children shall not
use, clean or play with this
appliance, which when not in use
should be secured out of their
reach.
Warning! To reduce the risk of fi re, personal injury, and
product damage due to a short circuit, never immerse your
8
ENGLISH
tool, battery pack or charger in fl uid or al-low a fl uid to fl ow
inside them. Corrosive or conductive fl uids, such as
seawater, certain industrial chemicals, and bleach or bleach
containing products, etc., Can cause a short circuit.
SPECIFIED CONDITIONS OF USE
The quick charger can charge Milwaukee M28 Li-Ion
batteries System M28 and V28 Li-Ion batteries System V28.
Do not use this product in any other way as stated for
normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
LI-ION BATTERIES
The rechargeable batteries are partially charged and
supplied in a non-operative state. Prior to initial use it is
necessary to activate the battery by plugging it into the
charger briefl y. The LED on the battery indicates the state of
charge.
If it is not used for long periods, the rechargeable battery will
switch to the non-operative state and needs to be
reactivated before reuse.
The state of charge can be read by pressing the button on
the rechargeable battery. The battery can be left in the
electric tool while the reading is taken but it must be
switched off at least one minute beforehand (otherwise the
display will be inaccurate). The number of LEDs illuminated
indicates the state of charge.
As a general principle, if the electric tool should fail to work
after inserting the rechargeable battery, then the battery
should be plugged into the charger. The displays on the
battery and charger will then provide information about the
condition of the battery.
In low temperatures work may continue at reduced output.
For an optimum life-time, after use, the battery packs have
to be fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below 27°C
and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
To obtain the longest possible battery life remove the battery
pack from the charger once it is fully charged.
CHARACTERISTICS
After inserting the battery into the reception of the charger
the battery will automatically be charged (red control lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once
the battery reaches the correct charging temperature
(0°C...65°C). The max. charging current is fl owing when the
temperature of the Li-Ion-battery is between 0°C and 65°C.
The battery's charging time is between 1 min and 60 min (at
3,0 Ah), depending on the state of discharge.
Once the battery is fully charged, the LED on the charger
changes from red to green.
It is not necessary to remove the battery after charging. The
battery can be stored permanently in the charger without the
danger of being overcharged.
If both LEDs fl ash alternately then the rechargeable battery
is either not fully pushed in or there is a fault with the battery
or charger. Take the charger and battery out of use
immediately for safety reasons and have them inspected by
a Milwaukee customer service centre.
All LED will fl ash 4x if the machine is overloaded. To
continue working, switch the machine off and then on again.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in
accordance with local, national and international provisions
and regulations.
• The user can transport the batteries by road without
further requirements.
• Commercial transport of Lithium-Ion batteries by third
parties is subject to Dangerous Goods regulations.
Transport preparation and transport are exclusively to be
carried out by appropriately trained persons and the
process has to be accompanied by corresponding experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and
insulated to prevent short circuit.
• Ensure that battery pack is secured against movement
within packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
MAINTENANCE
If the supply cord of this appliance is damaged, it must only
be replaced by a repair shop appointed by the manufacturer,
because special purpose tools are required
Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have
not been described, please contact one of our Milwaukee
service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Techtronic Industries GmbH,
Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Do not burn used battery packs.
Never charge a damaged battery pack.
Replace with a new one.
Do not dispose electric tools, batteries/
rechargeable batteries together with household
waste material.
Electric tools and batteries that have reached the
end of their life must be collected separately and
returned to an environmentally compatible
recycling facility.
Check with your local authority or retailer for
recycling advice and collection point.
This tool is only suitable for indoor use. Never
expose tool to rain.
Time-lag fuse 3.15 A
T3.15A
European Conformity Mark
National mark of conformity Ukraine
EurAsian Conformity Mark.
ENGLISH
9

Publicidad

loading